N61e V1.0 or Higher
12/23
Recommended charging temperature: NiCd 15°C
~
45 °C, Ni-MH 0°C
~
40 °C
N61e tries to detect the precise static
△
V(delta V) for the best possible full
charge. But the -
△
V is impacted by many factors, likely the charging rate,
surrounding temperature, as well as the batteries service time. It’s better to
terminate the charge by a series of conditions. Please refer
Table. NiCd &
NiMH Battery Charge Specification
to set up related parameters.
Table. NiCd & NiMH Battery Charge Specification
Charge Rate
Termination Comments
0.02-0.1C
Timer Limited at 160%C
0.1C
Timer 16 hours
0.1-0.2C
TCO: 55°C
Timer Limited:160%C(0.1C)
、
140%C (0.2C ).
0.25-1C
Δ
V:
NiCd 5-12 mV/cell, Ni-MH3-5 mV/cell
TCO:55°C
Timer Limited:125%C (0.5C ).
Edit Batt.M suit for your NiCd or NiMH Batteries
Par1.
Battery Type
While similar in many ways, Ni-MH and NiCd battery types perform a little
differently. It’s necessary to select the proper type for safe operating.
Par2.
Number of Cells in Series
Wrong setting for this parameter will cause
permanent damage to your packs or charger
and surroundings. It allows adjustment
from 1
…
18, or to be auto detected. Auto
detection select icon ‘A’ . The unit S means
cells in series.
Par3.
Capacity
Capacity is a very important parameter. It
will work on the operating control in many
ways. It’s mostly obvious that it determines
the charge current as working at
Page.1 (Par1/2/3/4)
▊
B NiMH6S 2.40Ah
STD CHG +1.2A
Page.1 (Par1/2/3/4)
▊
B NiMH6S 2.40Ah
CYC2 -2.4A +2.4A
Содержание N61e
Страница 23: ...N61e V1 0 or Higher 21 23 ...