USER MANUAL
©2019 Flash Technology, LLC
Page 8
Handheld Controller
– PAPI
3.3 Modes
3.3.1 Autonomous Mode
The Autonomous Mode setting is selected by the Handheld Controller:
Controlled Product
Setting
Handheld Controller
Key Sequence
PAPI Response
AUTO LOW
Press
AUTO LOW ENTER
LOW (Visible)
AUTO MED
Press
AUTO MED ENTER
HIGH (Visible)
AUTO HIGH
Press
AUTO HIGH ENTER
HIGH (Visible)
AUTO LOW IR
Press
AUTO LOW IR ENTER
INFRARED
AUTO MED IR
Press
AUTO MED IR ENTER
INFRARED
AUTO HIGH IR
Press
AUTO HIGH IR ENTER
INFRARED
AUTO LOW FLASH
Press
AUTO LOW FLASH ENTER
LOW (Flash not supported)
AUTO MED FLASH
Press
AUTO MED FLASH ENTER
HIGH (Flash not supported)
AUTO HIGH FLASH
Press
AUTO HIGH FLASH ENTER
HIGH (Flash not supported)
AUTO LOW IR FLASH
Press
AUTO LOW IR FLASH ENTER
INFRARED (Flash not supported)
AUTO MED IR FLASH
Press
AUTO MED IR FLASH ENTER
INFRARED (Flash not supported)
AUTO HIGH IR FLASH
Press
AUTO HIGH IR FLASH ENTER
INFRARED (Flash not supported)
In AUTO modes, the PAPI will stay in the desired mode until a LIGHTS OFF
command is sent from the Handheld Controller. The PAPI does not time out,
monitor battery states or check for ambient brightness condition.
The IR and FLASH keys are toggles. Press them once to select and a second time to deselect.
LOW (visible low) is used for night time operation.
HIGH (visible high) is used for day time operation.
IR (infrared) is used for NVG (Night Vision Goggle) operation.
Refer to LG-TM-253C-01, Technical Manual for Laser Guidance PAPI-253C operation.