USER MANUAL
©2019 Flash Technology, LLC
Page 9
Handheld Controller
– PAPI
3.3.2 Temporary Mode
The Temporary Mode setting is selected by the Handheld Controller:
The PAPI does not respond to TEMP commands to turn on the device.
The PAPI will change modes if already enabled in an AUTO MODE and a TEMP command is
received.
Example: PAPI set to AUTO LOW, receives a TEMP LOW IR command, PAPI changes to IR
mode
It is recommended the PAPI be controlled on a separate group to avoid this issue.
3.3.3 Standby Mode
Standby Mode turns off the output of the controlled product and waits for the next day-to-night transition. After this
transition, the controlled product enters its previous Autonomous Mode.
The PAPI interface does not have ambient brightness detection. A standby command responds
the same as Lights Off command.
3.3.4 Lights Off Mode
Lights Off Mode turns off the output of the controlled product indefinitely until it receives a command to turn its
output on.
1. Press
LIGHTS OFF
2. Press
ENTER
Lights Off Mode can be interrupted at any time by another Handheld Controller command.
3.3.5 Emergency Mode
Emergency Mode sets all controlled products in all groups to an emergency flash:
1. Press
EMERG 9 / ALL
(EMERG 9 / ALL indicator turns on)
2. Press
ENTER
To cancel Emergency Mode before this preset time:
1. Press
EMERG 9 / ALL
(EMERG 9 / ALL indicator turns off)
2. Press
ENTER
The PAPI will not FLASH in this mode but stay on steady