background image

 

 

 

USER MANUAL 

 

©2019 Flash Technology, LLC 

   

 

 

 

Page 9 

Handheld Controller 

– PAPI  

3.3.2  Temporary Mode 

 

The Temporary Mode setting is selected by the Handheld Controller: 

 

The PAPI does not respond to TEMP commands to turn on the device. 

 

The PAPI will change modes if already enabled in an AUTO MODE and a TEMP command is 
received. 

Example: PAPI set to AUTO LOW, receives a TEMP LOW IR command, PAPI changes to IR 
mode 

It is recommended the PAPI be controlled on a separate group to avoid this issue. 

3.3.3  Standby Mode 

  

Standby Mode turns off the output of the controlled product and waits for the next day-to-night transition. After this 
transition, the controlled product enters its previous Autonomous Mode. 

 

The PAPI interface does not have ambient brightness detection. A standby command responds 
the same as Lights Off command.

 

3.3.4  Lights Off Mode 

 

Lights Off Mode turns off the output of the controlled product indefinitely until it receives a command to turn its 
output on. 

1.  Press 

LIGHTS OFF

 

2.  Press 

ENTER

 

Lights Off Mode can be interrupted at any time by another Handheld Controller command. 

3.3.5  Emergency Mode 

 

Emergency Mode sets all controlled products in all groups to an emergency flash: 

1.  Press 

EMERG 9 / ALL

 (EMERG 9 / ALL indicator turns on) 

2.  Press 

ENTER

 

To cancel Emergency Mode before this preset time: 

1.  Press 

EMERG 9 / ALL

 (EMERG 9 / ALL indicator turns off) 

2.  Press 

ENTER 

 

 

The PAPI will not FLASH in this mode but stay on steady

 

 

 

 

Содержание PAPI

Страница 1: ...USER MANUAL 2019 Flash Technology LLC Handheld Controller PAPI Technical Support Email customerservice flashtechnology com Toll Free 1 800 821 5825 Fax 1 615 261 2600 Web flashtechnology com airfield ...

Страница 2: ...I Contents 1 0 Safety Usage 3 1 1 Battery Precautions 3 1 2 Wireless Precautions 3 1 3 Regulatory 4 1 4 Warranty Disclaimer 4 2 0 Introduction 5 2 1 Features 5 2 2 Applications 5 3 0 Operation 6 3 1 Theory of Operation 6 3 2 Features 6 3 3 Modes 8 4 0 Troubleshooting 10 ...

Страница 3: ...ry Precautions Use extreme caution when handling the battery This product is capable of generating enormous short circuit currents Remove all jewelry bracelets metal strap watches rings before attempting to handle or remove the battery Charge your battery periodically Permanent damage and reduced capacity will result if the battery is not correctly maintained The rate of battery self discharge is ...

Страница 4: ... interference to radio or television reception which can be determined by turning the equipment off or on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver i...

Страница 5: ...nd User password controls Secure 256 bit AES encryption Rechargeable lithium ion battery pack 2 2 Applications The Handheld Controller can control several products This manual indicates the responses for the following product only and is hereinafter referred to as the controlled product PAPI Flash Technology wireless interface to Laser Guidance Precision Approach Path Indicator product PAPI 253C R...

Страница 6: ...ne group Handheld Controller can control multiple or all groups at a time A controlled product can be reassigned to another group as required The Handheld Controller only sends wireless commands to the groups indicated by the Active Groups indicator LED s Controlled products not in the Active Groups will not respond to Handheld Controller commands In this example the Active Groups are 1 4 and 5 To...

Страница 7: ...hat group s last operating mode 5 min window of accepting grouping configurations is ended for controlled products When you are finished configuring groups exit CONFIG by 1 Press CONFIG CONFIG indicator starts flashing 2 Press ENTER CONFIG and SELECT GROUP indicators turn off When you add controlled products to a group products already part of that group are not affected In this way you can add to...

Страница 8: ...rted AUTO HIGH FLASH Press AUTO HIGH FLASH ENTER HIGH Flash not supported AUTO LOW IR FLASH Press AUTO LOW IR FLASH ENTER INFRARED Flash not supported AUTO MED IR FLASH Press AUTO MED IR FLASH ENTER INFRARED Flash not supported AUTO HIGH IR FLASH Press AUTO HIGH IR FLASH ENTER INFRARED Flash not supported In AUTO modes the PAPI will stay in the desired mode until a LIGHTS OFF command is sent from ...

Страница 9: ...n After this transition the controlled product enters its previous Autonomous Mode The PAPI interface does not have ambient brightness detection A standby command responds the same as Lights Off command 3 3 4 Lights Off Mode Lights Off Mode turns off the output of the controlled product indefinitely until it receives a command to turn its output on 1 Press LIGHTS OFF 2 Press ENTER Lights Off Mode ...

Страница 10: ...d Controller s and controlled product s UCS match or turn off UCS Controlled product s output is on or off Controlled product is unresponsive to wireless control Able to transmit wireless commands Unable to transmit wireless commands Environment Ensure all antennas are connected there is clear line of sight controlled products are within the possible range and the Handheld Controller is elevated I...

Отзывы: