INSTRUCTION MANUAL
Electrical winches LM500+/300S+
Réf : 1813000208
Page :
9/20
Version : 39/21
The power cable to the LM control box must be
flexible cable (Class 5). Beyond 30m, it must be
held in place by a suitable anchorage clamp.
EXTENSION SECTION (mm²) at
230V
Type :
0-50m
50-80m 80-
130m
130-
200m
3 wires
P+N+T
2.5²
13AWG
4.0²
11AWG
6.0²
9AWG
10.0²
7AWG
EXTENSION SECTION (mm²) at
110V
Type :
0-10m
10-20m 20-
30m
30-
50m
3 wires
P+N+T
2.5²
13AWG
4.0²
11AWG
6.0²
9AWG
10.0²
7AWG
If the LM winch is powered by a generator, check
that it delivers at least the voltage and power
required at the start of the winch (min 6kVA).
2.1.5.1
Hoist connection
-
Connect the button box to the socket on the
winch.
-
Connect the main power plug.
2.1.5.2
Commissioning
-
Unlock the emergency stop if
necessary
-
Press the UP button to lift or pull
the load
-
Press the DOWN button to lower
the load
At any time, in case of imminent danger
or need, press the Punch red button to
stop any movement of your hoist.
2.1.6
Installation of cables for lifting
Use protective gloves when handling wire
rope.
Check the condition of the cable and its length
(working 2m).
Check the condition of the hook and safety latch.
Do not use rotating hook on
our ropes.
Avoid the formation of loops when unwinding.
The end of the cable should be clean and sharp.
pour votre sécurité, n’utiliser que des câbles
FIXATOR
Put the end stopper on the wire rope (the spring
being directed to the winch). Block with an Allen
key.
Insert the end of the wire rope through the bottom
opening A. press the UP button on the pendant
control while pushing the wire rope so that it
engages in the throat of the pulley.
When the rope come out through hole B, continue
the movement so as to obtain a sufficient length of
wire rope.
PS : a second stopper is provided to stop the
descent; position the spring on the side of the
winch:
A
B
Document téléchargé par [email protected] - 2022-03-11 15:38:39