background image

 

EasyGrid LT User Guide

 

 

 

 
  

24 

 

 

5

 

Wiring information 

 

General

 

5.1

-

 

The following section is a recommendation, you must conform with your local electrical code. 

-

 

Use copper wire, solid or stranded. Copper wire ferrules can be used with stranded conductors. 

  

Terminal 
block 

Part number 

Manufacturer 

Recommended 
screwdriver blade  

Recommended 
torque 

Recommended 
strip length 

Wire size range 

Power 

1827635 

Phoenix Contact 

0.4 x 2.5mm 

0.23Nm 

7mm 

0.33 – 1.5mm

2

 

Analog 
output 

1803594 

Phoenix Contact 

0.4 x 2.5mm 

0.23Nm 

7mm 

0.2 – 1.5mm

2

 

System relay 

1803581 

Phoenix Contact 

0.4 x 2.5mm 

0.23Nm 

7mm 

0.2 – 1.5mm

2

 

RS-422/485 

1803604 

Phoenix Contact 

0.4 x 2.5mm 

0.23Nm 

7mm 

0.2 – 1.5mm

2

 

Relays 

1946570000 

Weidmuller 

0.6 x 3.5mm 

0.45Nm 

7mm 

0.2 – 2.5mm

2

 

 

 

 

Содержание EGD-LT

Страница 1: ...EasyGrid LT User Guide EasyGrid LT EGD LT User Guide MAN 00095...

Страница 2: ...its use No license is granted by implication or otherwise under any patent rights of FISO FISO s Commerce and Government Entities CAGE code under the North Atlantic Treaty Organization NATO is L0294...

Страница 3: ...Display Description 9 4 8 Navigation Flow chart 17 4 9 LED Indicators 18 4 10 4 10 1 System Status LED 18 4 10 2 Communication Status LED 18 4 10 3 Relay Alarm Status LED 19 4 10 4 Sensor Channel Sta...

Страница 4: ...EasyGrid LT User Guide iv Exclusions 34 8 3 Certification 34 8 4 Transportation 35 8 5 FISO Service Center 35 8 6 Product disposal 35 8 7...

Страница 5: ...uropean Union Directive and Standards Tests were performed externally at an independent accredited laboratory This guarantees the unerring objectivity and authoritative compliance of all test results...

Страница 6: ...IEC 60255 22 4 2008 Electrical fast transient immunity EFT 4kV Power Lines 4kV I O IEEE C37 90 1 2012 Fast Transient Surge Withstand Capability 4kV Power Lines 4kV I O IEC 61000 4 5 2005 IEC 60255 22...

Страница 7: ...adiation is below the level known to cause eye injury through accidental short term exposure However avoid prolonged exposure to light emitted from the fiber and do not stare directly at a light beam...

Страница 8: ...e written instructions provided Unpacking and Inspection 3 3 The EasyGrid LT monitor is shipped inside a carton designed to give maximum protection during shipment If the outside of the shipping carto...

Страница 9: ...it has multiple serial interfaces 1x USB and 1 x RS485 and 1x optional Ethernet communication port Standard supported communication protocols are Nortech and MODBUS Optional supported communication pr...

Страница 10: ...nit 1 Make sure that power is off when connecting the power supply to the unit 2 Connect the unit to the power supply using terminal block connectors V V 3 Wire the power input terminal block to a pow...

Страница 11: ...nnectors Always clean the fiber tip prior to insertion into the connector for optimum performance For details on connector handling and maintenance please refer to Cleaning Procedure section To connec...

Страница 12: ...he display menus Temp Displays the real time temperature read by the sensor or the sensor state when in error Analog Output Displays the real time analog output in mA read for each sensor Alarm Displa...

Страница 13: ...firmware version System Status Displays the state of the system when in error please refer to the trouble shooting section System Temperature Displays the current internal system temperature inside t...

Страница 14: ...currently in reading Alarm Description Off Alarm conditions are not met On Alarm conditions are met Exert Alarm is currently in exerciser mode this is to exercise the relay associated to the alarm wi...

Страница 15: ...80 Not very good Signal Description Sensor connect directly without patch cord or Easy Through Signal 88 Excellent 80 Signal 88 Good Signal 80 Not very good Sensor with a patch cord and or Easy Throu...

Страница 16: ...Channel as not yet an average value or is disable Statistic Execute reset action if confirm into the next window Confirm and go back to Temperature window Description Reset Reset the maximum minimum a...

Страница 17: ...ot yet ready Led Amber Channel is in reference mode Led Amber Blinking Sensor signal or light quality is good or is acquiring a new reference Led Red Error situation Led Red Blinking Sensor signal or...

Страница 18: ...19200 Factory Default Execute reset action if confirm into the next window Confirm and go back to window Temperature Description Reset Reset all the channel enable offset reference and analog output c...

Страница 19: ...Nortech 115200 bps or Modbus 19200 bpsor 9600 bps Address Device current address Config First Info data bits 8 bits Second Info Parity N None E Even O Odd Third Info stop bits 1 bit or 2 bits Date Ti...

Страница 20: ...EasyGrid LT User Guide 16 Confirmation No Cancel the current action Yes Confirm the current action Description Confirmation required for certain action execution C o n f i r m N o Y e s Confirmation...

Страница 21: ...EasyGrid LT User Guide 17 Navigation Flow chart 4 9...

Страница 22: ...0 protocol in function Amber Steady Nortech protocol in function Red Steady System Error or at least one sensor is Faulty When the LED blinks red an error situation related to the unit has occurred Re...

Страница 23: ...mode is selected the CH LED is green Each numbered LED corresponds to a sensor For example LED 1 corresponds to channel 1 LED 2 corresponds to channel 2 and so on The different LED states are Color St...

Страница 24: ...g analog outputs For a run of 100 m or less recommended gage is 24 AWG or greater The longer the run the smaller the recommended gage will be Recommendations call for shielded wire or for installation...

Страница 25: ...guration Switch RS 422 Mode RS 485 Mode RS422 RS485 Must be Left Must be Right RS422 RS485 Must be Left Must be Right RS485 EOL R Must be Left Right Adds a 120 End of Line resistor Left No end of line...

Страница 26: ...characteristic impedance value as the twisted wire used on the 485 network RS485 network termination resistors typical values are respectively 120 and Watt In Nortech mode it is possible to connect up...

Страница 27: ...EasyGrid LT User Guide 23 Physical dimensions 4 13...

Страница 28: ...Part number Manufacturer Recommended screwdriver blade Recommended torque Recommended strip length Wire size range Power 1827635 Phoenix Contact 0 4 x 2 5mm 0 23Nm 7mm 0 33 1 5mm2 Analog output 180359...

Страница 29: ...have 15W available for all the working temperature Power supply The EasyGrid LT has the following power requirement Voltage 24 Vdc 5 Power consumption 15 Watts FISO recommends the use of Power Supply...

Страница 30: ...are internally connected to the power supply ground and that ground is internally connected to the system GND at the M5 GND stud bottom left of the EasyGrid LT case The cables shields must be grounded...

Страница 31: ...arm on the system relay the relay close the circuit between the common C and the normally close NC terminal power failure or invalid reading of an active temperature channel or internal error of the E...

Страница 32: ...ing the link in one place You could use the integrated pull up and pull down resistors of the EasyGrid LT To do so place the Off RS485 Pull Up and the Off RS485 Pull Down dip switch to the right A and...

Страница 33: ...EasyGrid LT User Guide 29...

Страница 34: ...elays are open in alarm With failsafe operation a power failure equals an alarm For non failsafe operation the following are true Under non alarm conditions the relay closes the circuit between the co...

Страница 35: ...EasyGrid LT User Guide 31 6 Nortech Client Software Please refer to the Nortech Client software guide included on the CD...

Страница 36: ...ement display mode EasyGrid LT displays Code Error Description Possible Cause Possible Solution Low Error 1 Signal Too Low out of range Measured temperature is lower than the minimum permitted tempera...

Страница 37: ...ubleshooting section The Light is related to the strength of the light required to make an accurate reading on a sensor A sharp increase of the light value could indicate one of the following problems...

Страница 38: ...n removed The case has been opened The equipment serial number has been altered erased or removed The equipment has been misused neglected or damaged by accident Liability 8 2 FISO shall not be liable...

Страница 39: ...original packing material when shipping Keep the unit out of direct sunlight Avoid unnecessary shock and vibration FISO Service Center 8 6 If your product requires servicing contact your local FISO s...

Отзывы: