1.3 Check Methods
Check Point
Check Action (see if)
Corrective action
Tilt or deviation of axis
- The rotary table tip is
out of position
Reset the tip to the correct
location and lock up the axis
adjustment handles
Status of cables and hoses
- The electrical and
pneumatic hoses and
excessively twisted
bent or squeezed
- Air leakage between
pneumatic hoses and
fittings
Remove the causes of
twisting, bending or
squeezing
Cut away the damaged parts
of hose and make new
connections or replace
damaged fittings.
Appearance
- Damage from usage in
production or from
chemical erosion
Remove any obstacles from
the movement area of the
rotary tables
Keep rotary table surface
clean
Stability on work bench
- Rotary table is too
close to edge of the
work table
- Rotary table is
unstable
Rearrange the position of the
rotary table
Remove objects causing
instability
Balance out the rotary tables
base
Motor running condition
- Motor running slow or
over running angles or
under running angles
Replace cables
Replace motor driver card
Motion of drive cylinder
- Cylinder moving too
quickly
Inspect sensors for operation
ability
Inspect the flow regulator
fittings for functionality,
replace if necessary
Unfastened / loose bolts and
screws
- Loose Axis, bolts or
screws on the rotary
table
Using the correct sized Allen
key or screw driver tighten up
the loose parts
Internal and External wires
and connectors
- Misconnections or
loose wires
- No signals from I/O
Replace damaged cables
with appropriate spares