49
8.4.12 Compatible with new controller RG52I
Through RG52I controller, five function parameters of air conditioners can
be adjusted immediately. There is no need to change the chip anymore.
1, Auto restart function
Press “ADJUST” button, choose “F1”. Press “MODIFY” button, Press
“ADJUST” .Then choose “ON” or “OFF” button to active the auto restart function
or shut off the function. Press “CONFIRM” button at last.
2, Temp. compensation.
Press “ADJUST” button, choose “F2”. Press “MODIFY” button, Press “ADJUST”
to choose the temp. value(
0~6)
. Press “CONFIRM” button at last.
3, Anti-cold wind function
Press “ADJUST” button, choose “F3”. Press “MODIFY” button, Press “ADJUST”
to choose “1” or “2”. Press “CONFIRM” button at last.
“1” : intelligent defrosting mode.
“2” :common defrosting mode.
4, Indoor fan speed of when setting temp. is achieved.
Press “ADJUST” button, choose “F4”. Press “MODIFY” button, Press “ADJUST”
to choose “1” or “2” or “3”. Press “CONFIRM” button at last.
“1”: Indoor fan stops when setting temp. is achieved.
“2”: Indoor fan keeps at lowest fan speed when setting temp. is achieved.
“3”: Indoor fan keeps at setting fan speed when setting temp. is achieved.
5, Louver position memory function
Press “ADJUST” button, choose “F5”. Press “MODIFY” button, Press “ADJUST”
to choose “1” or “2” or “3”. Press “CONFIRM” button at last.
“1”: Louver position is not memorized.
“2”: Louver position is active, even when power off and AC shuts off.
“3”: Louver position is active, even when AC shuts off, while Inactive when power
off.
Содержание FSAIF-Pro-123AE2
Страница 8: ...8 O optional function ...
Страница 13: ...13 5 Wiring Diagram FSAIF Pro 93AE2 FSAIF Pro 183AE2 FSAIF Pro 243AE2 ...
Страница 14: ...14 FSAIF Pro 123AE2 ...
Страница 15: ...15 5 2 Outdoor Unit FSOAIF Pro 93AE2 ...
Страница 16: ...16 FSOAIF Pro 123AE2 ...
Страница 17: ...17 FSOAIF Pro 183AE2 ...
Страница 18: ...18 FSOAIF Pro 243AE2 ...
Страница 29: ...29 Use torque wrench to tighten the service port cap to a torque of 18N m Be sure to check for gas leakage ...
Страница 54: ...54 9 2 2 Indoor unit and outdoor unit communication protection error diagnosis and solution E1 ...
Страница 59: ...59 9 2 5 Open circuit or short circuit of temperature sensor diagnosis and solution E4 E5 F1 F2 F3 ...
Страница 61: ...61 9 2 7 IPM malfunction or IGBT over strong current protection diagnosis and solution P0 ...
Страница 62: ...62 9 2 8 Over voltage or too low voltage protection diagnosis and solution P1 ...
Страница 63: ...63 9 2 9 High temperature protection of compressor top diagnosis and solution P2 ...
Страница 64: ...64 9 2 10 Inverter compressor drive error diagnosis and solution P4 ...