840653
42
Display Code: 15
Condenser Fan Not Off.
Reason:
Condenser fan fault. The condenser fan is still rotating. Either the fan or the
power/control module is faulty.
Action:
Check the condenser fan wiring, connections and fan function. If OK, replace the
power/control module. If still faulty, replace the display module.
Display Code: 16
Condenser Fan Not On.
Reason:
Condenser fan fault. The condenser fan is rotating less than expected. Either the
wiring is open circuit or the fan is faulty.
Action:
Check the condenser fan wiring, connections and fan function. If OK, replace the
power/control module. If still faulty, replace the display module.
Display Code: 17
Evaporator Fan Not Off.
Reason:
Evaporator fan fault. The evaporator fan is still rotating. Either the fan is faulty or the
power/control module is faulty.
Action:
Check the evaporator fan wiring, connections and fan function. If OK, replace the
power/control module. If still faulty, replace the display module.
Display Code: 18
Evaporator Fan Not On.
Reason:
Evaporator fan is fault. The evaporator fan is rotating less than expected. Either the
wiring is open circuit or the fan is faulty.
Action:
Check the evaporator fan wiring, connections and fan function. If OK, replace the
power/control module. If still faulty, replace the display module.
Display Code: 105
Communications
Fault.
Reason:
There is a communications fault between the cabinet module, the display module/user
interface and the power/control module. It could be in any of the modules or in the
wiring harness.
Action:
1. Replace the display module/user interface. Wait 30 seconds after re-applying
power, then retest. If fault still exists:
2. Refit original display module/user interface. Check continuity of harness between
the display module/user interface and the cabinet module. If faulty, replace. If fault
still exists:
3. Replace the cabinet module. Wait 30 seconds after re-applying power, then retest.
If fault still exists:
4. Refit original cabinet module. Replace the power/control module.
10.1.3
Diagnostic Mode
The CoolDrawer is fitted with a diagnostic system to help the service technician in testing the drawer and
obtaining information that will assist in locating the fault.
1
2
To Enter Diagnostic Mode:
•
Open the drawer.
•
Press the
LOCK
button for 3 seconds to unlock the control panel.
•
Within 15 seconds, press and hold the
LOCK
button, then within 1 second press the
FUNCTION
SELECT
button. Hold for 3 seconds. This shows the compartment temperature.
The
WARMER
or
COLDER
button can now be used to scroll through the diagnostic menu.
Having entered diagnostic mode, the compartment temperature is displayed.
•
Press the
COLDER
button once. The data download mode is entered.
Содержание RB36S25MKIW
Страница 1: ...840653 Service Manual CoolDrawer Models RB36S25MKIW RB90S64MKIW ...
Страница 12: ...840653 12 3 4 Integrated Panel Preparation ...
Страница 14: ...840653 14 3 5 Create Cut Outs In Frame 3 6 Locate And Secure Install Brackets ...
Страница 15: ...840653 15 3 7 Attach Inlet And Outlet Vent Ducts 3 8 Attach Power Cord And Trim Brackets ...
Страница 16: ...840653 16 3 9 Move Product Into Cavity 3 10 Fit Drawer Panel Attachment Hooks ...
Страница 17: ...840653 17 3 11 Attach Drawer Panel To Front Of Drawer ...
Страница 18: ...840653 18 3 12 Secure Trim Brackets To Cabinetry 3 13 Attach Trims To Sides Of Cabinetry ...
Страница 19: ...840653 19 3 14 Attach False Panel 3 15 Check Operation ...
Страница 53: ...840653 53 11 WIRING DIAGRAMS Ω Ω Ω Ω Ω Ω Ω Ω Ω Ω ...
Страница 54: ...840653 54 ...
Страница 77: ...840653 77 ...