840653
13
3.4.1
Integrated Panel Material
•
16 – 20mm (
5
/
8
–
13
/
16
”) panel thickness (18mm (
3
/
4
”) recommended).
•
Adequately sealed to withstand moisture (50
O
C/122
O
F @ 80% RH).
3.4.2
Height Of Drawer Panel
The following information is required to correctly define your Drawer panel height:
Dimension
Data
Source
A
Reveal dimension
Your kitchen designer
B
Height between top of internal shelf and underside of benchtop
Your kitchen designer
C
Bottom face of Drawer panel to top of internal shelf
Min. 152mm (6”)
Max. 184mm (7
1
/
4
”)
D
Drawer panel height
Calculated from A, B & C
To calculate D complete the following equation:
D = B - A - C
Example: B
=
686mm
(27”)
A
=
20mm
(
13
/
16
”)
C
=
184mm
(7
1
/
4
”)
Therefore D = 686mm – 20mm – 184mm = 482mm (27” -
13
/
16
” - 7
1
/
4
” = 18
15
/
16
”)
3.4.3
Height Of False Panel
Determine the height of the false panel according to the individual kitchen cabinetry requirements,
maintaining a 4mm (
3
/
16
”) gap between panels.
The Fisher & Paykel prefinished panel width is 896mm (35”).
Содержание RB36S25MKIW
Страница 1: ...840653 Service Manual CoolDrawer Models RB36S25MKIW RB90S64MKIW ...
Страница 12: ...840653 12 3 4 Integrated Panel Preparation ...
Страница 14: ...840653 14 3 5 Create Cut Outs In Frame 3 6 Locate And Secure Install Brackets ...
Страница 15: ...840653 15 3 7 Attach Inlet And Outlet Vent Ducts 3 8 Attach Power Cord And Trim Brackets ...
Страница 16: ...840653 16 3 9 Move Product Into Cavity 3 10 Fit Drawer Panel Attachment Hooks ...
Страница 17: ...840653 17 3 11 Attach Drawer Panel To Front Of Drawer ...
Страница 18: ...840653 18 3 12 Secure Trim Brackets To Cabinetry 3 13 Attach Trims To Sides Of Cabinetry ...
Страница 19: ...840653 19 3 14 Attach False Panel 3 15 Check Operation ...
Страница 53: ...840653 53 11 WIRING DIAGRAMS Ω Ω Ω Ω Ω Ω Ω Ω Ω Ω ...
Страница 54: ...840653 54 ...
Страница 77: ...840653 77 ...