The Panda Generator
Page 14 Panda PMS AGT-DC 10000 - Chapter A: The Panda Generator
Water-cooled exhaust elbow
The manifold is cooled by means of the
internal cooling system (freshwater). The
cooling water filler necks on the casing of
the elbow may not be opened. These cool-
ing water necks are only required to fill the
motor with cooling water in cases of repair.
The normal cooling water controls may
only be carried out at the external expan-
sion tank.
Fig. A.17: Water-cooled exhaust elbow
A.2.4 Components of the fuel system
External fuel pump
The Panda generator is always supplied
with an external, electrical (12 V of DC) fuel
pump. The fuel pump must be always
installed in the proximity of the tank. The
electrical connections with the lead planned
for it are before-installed at the generator.
Since the suction height and the supply
pressure are limited, it can be sometimes
possible that for reinforcement a second
pump must be installed.
Fig. A.18: External fuel pump
Connecting pieces for the fuel pipe
1. Fuel intake
2. Fuel backflow
Fig. A.19: Fuel connections
1
2