Generator Faults
9.2.16
Kapitel/Chapter 8: Generator Faults - Seite/Page 127
Lack of fuel.
Check fuel supply.
Glow-plugs not working correctly.
Check glow plugs and heating time.
Too much air in fuel lines.
Test fuel system for leakage. Bleed air from fuel system (refer to section
„Bleeding Air from Fuel System“).
Fuel-filter blocked.
Replace fuel filter.
Cause
Solution