Kapitel/Chapter 5: Installation Instructions - Seite/Page 59
center line. See the following pictures:
Fig. 5.7.3.1-1: Ideal position of the waterlock
In Fig. 5.7.3.1-1, the waterlock is mounted in center underneath the generator. When the ship tilts, the position of the
waterlock related to the critical point at the exhaust hose, changes only slightly.
Fig. 5.7.3.1-2: Tilted position 15 degrees
Tilted position 15 degrees - Fig. 5.7.3.1-2
The distance from the exhaust elbow to the hydrostatic head has derated to 540 mm.
Fig. 5.7.3.1-3: Tilted position 30 degrees
Tilted position 30 degrees - Fig. 5.7.3.1-3
The distance of the water level, even in ideal position, changes that only 458 mm distance remain. So the critical
distance is under-run already.