![Fischer Panda 15000i PMS Скачать руководство пользователя страница 172](http://html1.mh-extra.com/html/fischer-panda/15000i-pms/15000i-pms_manual_2294291172.webp)
Warnings and error messages
Seite/Page 172 - Kaptitel/Chapter 15: Warnings and error messages
4.5.16
15.2.3 Bus errors
If the communication connection is lost on the Fischer Panda bus, an error is output on the display after a period of
10 seconds:
Fig. 15.2.3-1: Error: „NO CONNECTION“, error in the
communication (Fischer Panda bus)
This error will occur if at least one of the two data lines
of the Fischer Panda bus is disconnected. Once the
connection is restored, the error message can be
acknowledged with the Start/Stop button.
If the communication connection is lost, the generator shall be secured (open battery disconnect switches), and all
plug-in connections and cables shall be checked for firm seating or damage.
15.3 The error memory of the iControl 2 Panel
From Software version PiC2_2.9 (control board) and PiP2_2.9 (control panel) the Panda iControl2 has got an error
memory which shows the last six errors in the plain text.
P8-P50 marine
Cylinder head temperature
Delay
90 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
70 °C
1 s
75 °C
1 s
P8-P50 vehicle
Cylinder head temperature
Delay
95 °C
5 s
100 °C
5 s
Winding temperature
Delay
160 °C
5 s
165 °C
5 s
Exhaust manifold temperature
Delay
100 °C
1 s
105 °C
1 s
P15000i marine
Cylinder head temperature
Delay
90 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
70 °C
2 s
75 °C
2 s
P15000i vehicle
Cylinder head temperature
Delay
90 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
95 °C
2 s
100 °C
2 s
All generator types
Starter battery voltage low
Delay
11.8 V
30 s
10.8 V
30 s
Starter battery voltage high
15.0 V
5 s
--
--
Generator type
Warning/fault
Warning threshold
Fault threshold
Содержание 15000i PMS
Страница 10: ...Seite Page 10 Kapitel Chapter 2 4 5 16 Leere Seite Intentionally blank...
Страница 70: ...Installation Instructions Seite Page 70 Kaptitel Chapter 5 Installation Instructions 4 5 16...
Страница 112: ...Tables Seite Page 112 Kaptitel Chapter 9 Tables 4 5 16...
Страница 136: ...Inverter Panda PMGi Seite Page 136 Kaptitel Chapter 10 Inverter Panda PMGi 4 5 16 Leere Seite Intentionally blank...
Страница 158: ...Seite Page 158 Kapitel Chapter 12 General operation 4 5 16 Leere Seite Intentionally blank General operation...
Страница 168: ...Seite Page 168 Kapitel Chapter 14 Maintenance 4 5 16 Leere Seite Intentionally blank Maintenance...
Страница 176: ...Seite Page 176 Kapitel Chapter 16 Annex 4 5 16 Leere Seite Intentionally blank Annex...