![Fischer Panda 15000i PMS Скачать руководство пользователя страница 109](http://html1.mh-extra.com/html/fischer-panda/15000i-pms/15000i-pms_manual_2294291109.webp)
Tables
4.5.16
Kapitel/Chapter 9: Tables - Seite/Page 109
9.5
Cable cross section
Fig. 9.5.0-1: Cable cross section
9.6
Engine oil
9.6.1 Engine oil classification
9.6.1.1 Operating range:
The operating range of an engine oil is determined by SAE class. „SAE“ is for the union of American auto engineers
(Society of Automotives Engineers).
The SAE class of an engine oil only informs over the viscosity of the oil (larger number = more viscous, smaller
number = more highly liquidly) e.g. to 0W, 10W, 15W, 20, 30, 40. The first number shows the liquid of the oil with
cold weather, the second number refers to the fluidity with heat. Complete yearly oils have usually SAE classes of
SAE 10W-40, SAE 15W-40 etc.
9.6.1.2 Quality of oil:
The quality of an engine oil is specified by the API standard („American Petroleum Institutes“).
The API designation is to be found on each engine oil bundle. The first letter is always a C.
Panda PMS 50 MB
40
30
60
8
8
Panda PMS 60 MB
40
40
60
8
8
Panda PMS 75 MB
40
30
60
8
8
Panda PMS-HD 7,5-4 KU
25
20
40
8
8
Panda PMS-HD 09-4 KU
25
20
50
8
8
Panda PMS-HD 12-4 KU
25
20
50
8
8
Panda PMS-HD 17-4 KU
25
25
60
8
8
Panda PMS-HD 22-4 KU
30
30
60
8
8
Panda PMS-HD 30-4 KU
30
30
60
8
8
Panda PMS-HD 40-4 KU
30
30
60
8
8
Panda PMS-HD 60-4 DZ
-
-
-
-
-
Panda PMS-HD 70-4 DZ
-
-
-
-
-
Panda PMS-HD 85-4 DZ
-
-
-
-
-
Panda PMS-HD 110-4 DZ
-
-
-
-
-
Panda PMS-HD 130-4 DZ
-
-
-
-
-
length
1 - 3 m
4 - 6 m
7 - 10 m
11 - 15 m
16 - 20 m
16 mm²
70 A
63 A
55 A
48 A
42 A
25mm²
112 A
100 A
88 A
75 A
63 A
35mm²
145 A
130
110
100 A
90 A
50mm²
225 A
200 A
175 A
150 A
125 A
70mm²
275 A
250 A
225 A
195 A
170 A
95mm²
340 A
300 A
280 A
260 A
220 A
Generator type
Ø Cooling water conduit
Ø Exhaust conduit
[mm]
Ø Fuel conduit
Freshwater
[mm]
Seawater
[mm]
Supply
[mm]
Return
[mm]
Содержание 15000i PMS
Страница 10: ...Seite Page 10 Kapitel Chapter 2 4 5 16 Leere Seite Intentionally blank...
Страница 70: ...Installation Instructions Seite Page 70 Kaptitel Chapter 5 Installation Instructions 4 5 16...
Страница 112: ...Tables Seite Page 112 Kaptitel Chapter 9 Tables 4 5 16...
Страница 136: ...Inverter Panda PMGi Seite Page 136 Kaptitel Chapter 10 Inverter Panda PMGi 4 5 16 Leere Seite Intentionally blank...
Страница 158: ...Seite Page 158 Kapitel Chapter 12 General operation 4 5 16 Leere Seite Intentionally blank General operation...
Страница 168: ...Seite Page 168 Kapitel Chapter 14 Maintenance 4 5 16 Leere Seite Intentionally blank Maintenance...
Страница 176: ...Seite Page 176 Kapitel Chapter 16 Annex 4 5 16 Leere Seite Intentionally blank Annex...