![Fischer Connectors FO2-4 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/fischer-connectors/fo2-4/fo2-4_assembly-instruction-manual_2294252017.webp)
Assembly instructions Rev6.0
17
This document is the property of Fischer Connectors.
This document must not be reproduced or distributed, in whole or in part, without prior written permission of Fischer Connectors.
Position the Ferrule O-ring “C” on
the Ferrule “D” as shown on the
top left picture.
Slide the Spring “E” and Termini
Closure “F” at the back of the
Ferrule “D” and assemble them
into the Termini Housing “B”.
Position the Housing O-ring “A”
on the Termini Housing “B” as
shown on the left picture.