23
Troubleshooting
Fault
Probable Cause
Solution
Water changes color
or becomes cloudy.
Rower is in direct
sunlight or has not
had water treatment.
Local tap water is of
poor quality.
Change Rower location to reduce
direct exposure to sunlight. Add
water treatment or change Tank
water as directed in the water
treatment section of this manual.
Consider using distilled water to
refill Tank.
Rower Belt slipping
off Belt/ Bungee Pul-
ley.
Bungee not under
enough tension.
Recoil not strong
enough
Tighten Bungee cord following
the instructions in "reattaching
the Rower Belt" section of this
manual.
Inconsistent readings
on the Monitor for
500meter split time
and SPM (strokes per
minute).
Sensor gap
Faulty Sensor
Sensor has moved out
of position
Wiring harness
Use the back cover of the Monitor
as a “Gap tool” to check the gap
between Sensor Head and Magnetic
Ring, or see if the Sensor head has
moved out of position.
Please contact your nearest FDF
customer service center for details
The Monitor does not
illuminate after
battery
installation.
Batteries installed
incorrectly or need
replacing.
Replace/reinstall batteries in
correct position and try again.
If the LCD screen fails to
illuminate, try rotating the
batteries slightly in the Monitor.
If this fails, contact your local
service center.
The Monitor screen
illuminates, but does
not register when
rowing.
Loose or failed
connection.
Sensor gap too wide
Check that the Monitor Lead is
connected properly. If it is
connected then contact your local
service center. Check Sensor gap.
The Monitor LEVEL is
not synchronized with
the Tank LEVEL.
Monitor LEVEL needs
to be recalibrated.
Please refer to "Calibration
Procedure" page 18 of this manual.