RESTORE REPORT CODES (

70 – 

76) 

70

  ALARM RESTORE RPT CODE

 

 

 

  

  [0] 

See box on previous page. 

71

  TROUBLE RESTORE RPT CODE

 

    |       [11] 

See box on previous page. 

72

  BYPASS RESTORE RPT CODE

 

    |       [00] 

See box on previous page. 

73

  AC RESTORE RPT CODE

 

    |       [00] 

See box on previous page. 

74

  LOW BAT RESTORE RPT CODE

 

    |       [11] 

See box on previous page. 

75

  RF XMTR LO BAT RST RPT CODE

 

    |       [00] 

See box on previous page. 

UL: must be enabled if wireless devices are used 

76 

TEST RESTORE RPT CODE

 

    |       [00] 

See box on previous page. 

OUTPUT AND SYSTEM SETUP (

77 – 

93) 

 77 

DAYLIGHT SAVINGS TIME 

 START\END 

MONTH 

    |       [4][10]

 

0 = Disabled 
1-12 = January-September (1 = Jan, 2 = Feb, etc) 
#+10 = October; #+11 = November; #+12 = December

 

 

 78 

DAYLIGHT SAVINGS TIME 

 START\END 

WEEKEND 

    |      [1][5]

 

0 = disabled, 1 = first, 2 = second, 3 = third 
4 = fourth, 5 = last, 6 = next to last, 7 = third to last

 

 79, 

 80, 

 81, 

 82  Menu Modes

 

These are Menu Mode commands, not data fields, for Output Device Mapping, Output Programming, Zone List Programming, and Alpha 
Programming respectively. See page 2 and their respective sections in the Installation and Setup Guide for procedures.  

 

83 

TIME ZONE 

 

 

  

  [0]

 

0 =Eastern, 1 = Central 
2 = Mountain, 3 = Pacific

 

 

84 

AUTO STAY ARM 

 

 

  

  [0]

 

0 = no, 1 = partition 1 only 
2 = partition 2 only, 3 = both partitions

 

 

85 

CROSS ZONE TIMER 

 
 

This option not for use in UL installations.

 

 

 

  

  [4] 

 

0 = 15 seconds 

6 = 2-1/2 min 

#+12 = 8 min 

1 = 30 seconds 

7 = 3 min 

#+13 = 10 min 

2 = 45 seconds 

8 = 4 min 

#+14 = 12 min 

3 = 60 seconds 

9 = 5 min 

#+15 = 15 min 

4 = 90 seconds 

#+10 = 6 min 

5 = 2 minutes 

#+11 = 7 min  

(assign cross zones on zone list 4, with *81 Menu mode)

 

86 

CANCEL VERIFY KEYPAD DISPLAY 

 

 

  

  [1]

 

0 = no, 1 = yes (canceled alarm display is automatically 
disabled if field *199 is set to “1,” 2-digit display).

 

 

87 

MISC. FAULT DELAY TIME 

 

(used with Configurable Zone Types “digit 6”)

 

 

 

  

  [0]

 

0 = 15 seconds 

6 = 2-1/2 min 

#+12 = 8 min 

1 = 30 seconds 

7 = 3 min 

#+13 = 10 min 

2 = 45 seconds 

8 = 4 min 

#+14 = 12 min 

3 = 60 seconds 

9 = 5 min 

#+15 = 15 min 

4 = 90 seconds 

#+10 = 6 min 

5 = 2 minutes 

#+11 = 7 min 

UL: may only be used on non-burglar alarm/ non-fire alarm 
zones when used in fire and/or UL burglar alarm installation 

 

89 

EVENT LOG FULL REPORT CODE 

    |       [00]

 

See box on previous page for report code entries.

 

 

90

  EVENT LOG ENABLES 

 

 

  

  [15] 

 

NOTE

System messages are 

logged when any non-zero 
selection is made. 

0 = None; 1 = Alarm/Alarm Restore 
2 = Trouble/Trouble Restore;   
4 = Bypass/Bypass Restore;  
8 = Open/Close.

 Example:  To select “Alarm/Alarm 

Restore”, and “Open/Close”, enter 9 (1 + 8);  To select 
all, enter #15.

 

 

91

 OPTION 

SELECTION 

 

 

 

 

  

  [9] 

 

E.g. (multiple choice): for AAV 
(4) plus Exit Delay restart (8) 
enter # + 12; for all (1 + 2 + 4 + 
8), enter # + 15.

 

0 = None  

 

1 = Local Lockout 
2 = Sounder Delay 
 

 UL: if used, entry delay (*35) must be 30 sec. max.

4 = AAV  UL: must use UVCM module 
8 = Exit Delay Restart/Reset UL: must be disabled 
SIA Installations: Exit Delay should be enabled.

 

 

92

  PHONE LINE MONITOR ENABLE 

 
 

 UL: see Inst. Instructions for requirements 

 

 

  

 

 

 

  

  [0,0]

 

Entry 1:

: 0 = disabled, 1-15 = 1 min - 15 min  

 

(#+10 = 10 min; #+11 = 11 min; #+12 = 12 min; 
#+13 = 13 min; #+14 = 14 min; #+15 = 15 min) 

Entry 2

:  

0 = Keypad display when line is faulted 
1 = Keypad display plus keypad trouble sound 
2 = Same as “1”, plus programmed output device 
STARTS. If either partition is armed, external sounder 
activates also.

 NOTE: 

Output Device must either be 

programmed to be STOPPED in field 

80 or 

STOPPED by Code + # + 8 + output number.

 

 

93

  No. OF REPORTS IN ARMED PERIOD 

 

PER ZONE (Swinger Suppression) 

 

 

  

  [1]

 

0 = Unlimited Reports   
1 = 1 report pair; 2 = 2 report pairs 
SIA Installations: Must be set for option 1 or 2.

 

Содержание FA168C-GP

Страница 1: ... Sy ys st te em m Programming Guide ON OFF ARMED READY A B C D 6 4 7 BYPASS 9CHIME 3STAY 5TEST 8CODE 0 2AWAY 1OFF MAX INSTANT READY FA260 R ARMED READY FA560 6 4 7 BYPASS 9CHIME 3STAY 5TEST 8CODE 0 2AWAY 1OFF MAX INSTANT READY R AWAY STAY PAGE K5305 5GPPRV2 9 04 Rev A ...

Страница 2: ...9 or 4204 Relay modules Powerline Carrier devices or on board triggers 81 Zone List Programming Zone Lists for relay powerline carrier activation chime zones pager zones etc 82 Alpha Programming Zone alpha descriptors INITIALIZE DOWNLOAD and RESET DEFAULTS 96 Initializes download ID and subscriber account number 97 Sets all data fields to original factory default values TO EXIT PROGRAMMING MODE 98...

Страница 3: ... must be minimum 16 min option 4 34 EXIT DELAY 60 60 Part 1 Part 2 Common zones use same delay as partition 1 00 96 0 96 secs 97 120 secs 98 180 secs 99 240 secs SIA Installations minimum exit delay is 45 seconds UL see inst instr for requirements 35 ENTRY DELAY 1 zone type 01 30 30 Part 1 Part 2 Common zones use same delay as partition 1 00 96 0 96 seconds 97 120 seconds SIA Installations 98 180 ...

Страница 4: ...st be 15 max 55 DYNAMIC SIGNALING PRIORITY 0 0 Primary Dialer first 1 Long Range Radio first For UL Commercial Burglary installations that use a DACT and LRR this field must be 0 56 57 58 Menu Modes These are Menu Mode commands not data fields for Zone Programming Function Key Programming and Expert Mode Zone Programming respectively See page 2 and their respective sections in the Installation and...

Страница 5: ...y disabled if field 199 is set to 1 2 digit display 87 MISC FAULT DELAY TIME used with Configurable Zone Types digit 6 0 0 15 seconds 6 2 1 2 min 12 8 min 1 30 seconds 7 3 min 13 10 min 2 45 seconds 8 4 min 14 12 min 3 60 seconds 9 5 min 15 15 min 4 90 seconds 10 6 min 5 2 minutes 11 7 min UL may only be used on non burglar alarm non fire alarm zones when used in fire and or UL burglar alarm insta...

Страница 6: ...ional prefix characters up to 16 digits 0 9 11 12 13 2 second pause 165 PAGER 2 REPORT OPTIONS 0 0 0 Part 1 Part 2 common See field 162 for reporting options Select for each partition use zone list 10 if using options 12 or 13 166 PAGER 3 PHONE No Enter up to 20 digits 0 9 11 12 13 2 second pause 167 PAGER 3 CHARACTERS Enter the optional prefix characters up to 16 digits 0 9 11 12 13 2 second paus...

Страница 7: ... 2 AUI 1 Must set AUI address to 1 AUI 2 Must set AUI address to 2 Enter each touch screen AUI device s home partition 0 disabled 1 partition 1 2 partition 2 3 partition 3 common NOTE Use of AUI does not affect the number of standard keypads supported AUI Compatibility Note To ensure proper AUI device operation connect only to controls having microprocessor version 3 0 or higher and use AUI device...

Страница 8: ... disarmed 3 never show any alarms trbles faults 0 no 4 power reset after fault by code OFF 12 verification see zone type 16 0 no 1 delay 1 2 delay 2 0 no 4 use exit delay 0 no 8 yes see note 2 Entry 7 fault display power reset verification Entry 8 entry delay 1 entry delay 2 exit delay interior zone type ENTRY 9 ENTRY 10 Alarm Sounds Use Bell Timeout Respond as Fire Zone Trouble Sounds Chime when ...

Страница 9: ... BR 52 1 BR 53 1 BR 54 1 BR 55 1 BR 56 1 BR 57 1 BR 58 1 BR 59 1 BR 60 1 BR 61 1 BR 62 1 BR 63 1 BR 64 1 BR 95 15 N A N A N A keypad 1 96 09 N A N A N A keypad 3 99 07 N A N A N A keypad NOTES Zone Type see chart on page 12 Report Code enabled if any digit entered as 1st digit Hardwire Type zns 1 8 0 EOL 3 ZD 1 NC 4 DB 2 NO Input Type 2 AW zones 9 48 3 RF zones 9 48 4 UR zones 9 48 5 BR zones 49 6...

Страница 10: ... 80 and 81 Applicable only if Relays and or Powerline Carrier Devices are to be used 79 RELAY POWERLINE CARRIER DEVICE X 10 MAPPING Must program before using 80 OUTPUT TYPE OUTPUT TYPE Relay X10 Relay X10 Output No Module Addr Pos 1 4 Unit No Description Output No Module Addr Pos 1 4 Unit No Description 01 09 02 10 03 11 04 12 05 13 06 14 07 15 08 16 17 On Board Trigger 1 norm output 1 18 On Board...

Страница 11: ...ction 0 off 1 close 2 secs 2 stay closed 3 pulse 4 toggle 5 duration 1 6 duration 2 duration is set in program field 177 Output Number 1 18 Device Type R relay T trigger X X10 ZONE TYPE SYSTEM OPERATION Choices for Zone Types are 00 Not Used 05 Trouble Day Alarm Night 10 Interior w Delay 23 No Alarm Response 01 Entry Exit 1 06 24 Hr Silent 12 Monitor Zone 24 Silent Burglary 02 Entry Exit 2 07 24 H...

Страница 12: ...on or to a zone containing monitoring devices such as water or temperature sensors Sends a report to the central station and provides a keypad alarm sound No bell output is provided Type 09 Fire Provides a fire alarm on short circuit and a trouble condition on open circuit A fire alarm produces a pulsing bell output This zone type is always active and cannot be bypassed Note Hardwired zone 1 shoul...

Страница 13: ...is faulted all alarm sounding and dialer reporting stops except for fire alarms which immediately terminate the voice session and cause a fire report to be sent When the zone is restored session ended sounding resumes if bell timeout has not expired and reports that were stopped are sent Types 90 93 Installer Defined These zone types can be programmed for various custom responses See data fields 1...

Страница 14: ...7 PERIMETER 148 PHONE 150 POINT 151 POLICE 152 POOL 153 POWER R 155 RADIO 156 REAR 157 RECREATION 159 REFRIGERATION 160 RF 161 RIGHT 162 ROOM 163 ROOF S 164 SAFE 165 SCREEN 166 SENSOR 167 SERVICE 168 SHED 169 SHOCK 170 SHOP 171 SHORT 173 SIDE 174 SKYLIGHT 175 SLIDING 176 SMOKE 178 SONS 179 SOUTH 180 SPRINKLER 182 STATION 184 STORE 185 STORAGE 186 STORY 190 SUPERVISED 191 SUPERVISION 192 SWIMMING 1...

Страница 15: ...Default Templates For 5804 Loop Function Zone Type For 5804BD Loop Function Zone Type TEMPLATE 1 1 No Response 23 TEMPLATE 4 1 No Response 23 2 Disarm 22 2 No Response 23 3 Arm Away 21 3 Arm Away 21 4 No Response 23 4 Disarm 22 TEMPLATE 2 1 No Response 23 TEMPLATE 5 1 No Response 23 2 Disarm 22 2 Arm Stay 20 3 Arm Away 21 3 Arm Away 21 4 Arm Stay 20 4 Disarm 22 TEMPLATE 3 1 24 hour audible 7 TEMPL...

Страница 16: ...00 OHMS PLUS EOLR RESPONSE ZONES 1 8 10 350 OR 700 MSEC PROGRAMMABLE 8 PIN CONNECTOR USED FOR 1361X10 TRANSFORMER CONNECTIONS AND FOR ON BOARD TRIGGERS SEE INSTRUCTIONS 7 8 USE SA4120XM 1 CABLE TIP BROWN THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT ANY INTERFERENCE ...

Отзывы: