Dialer Programming (
∗∗∗∗
40 –
∗∗∗∗
50)
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*40
PABX Access Code or
Call Waiting Disable
Enter up to 6 digits if PABX is needed to
access an outside line. Do not fill unused
spaces. 0–9, # + 11 for ‘
∗
’, # + 12 for ‘#’, # +
13 for a pause (2 seconds)
SIA-Compliant Controls:
If call waiting is used,
enter call waiting disable digits as described, and
also set Call Waiting Disable option in field *91.
To clear entries from field, press
∗
40
∗
. If fewer than 6 digits need to
be entered, exit by pressing [
∗
], which advances to the next field.
Call Waiting: If the subscriber’s phone service has “call waiting”
(and is not using PABX), enter “*70” (“# + 11”) plus “# + 13” (pause)
as the PABX entry to disable “call waiting” during control panel calls.
If the subscriber does not have “call waiting” and is not using PABX,
make no entry in this field.
NOTES: 1. The call waiting disable feature cannot be used on a
PABX line. 2. Using Call Waiting Disable on a non-call waiting line
will prevent successful communication to the central station.
*41
Primary Phone No.
Enter up to 20 digits. Do not fill unused
spaces.
0–9, # + 11 for ‘
∗
’, # + 12 for ‘#’, # + 13 for a
pause (2 seconds)
If you enter fewer than 20 digits, exit by pressing [
∗
]. To clear entries
from field, press
∗
41
∗
.
NOTE: Backup reporting (in which 8 calls are made to the secondary
phone number if no kissoff is received after 8 attempts to the
primary number) is automatic only if there is a secondary phone
number (field
∗
42).
*42
Secondary Phone No.
Enter up to 20 digits. 0–9, # + 11 for ‘
✱
’, # +
12 for ‘#’, # + 13 for a pause (2 seconds)
If you enter fewer than 20 digits, exit by pressing [
∗
]. To clear entries
from field, press
∗
42
∗
. See backup reporting note for field
∗
41.
Don’t fill unused spaces.
*43
Part. 1 Primary Subs. Acct. No.
Enter digits 0–9; # + 11 for B, # + 12 for C,
# + 13 for D, # + 14 for E, # + 15 for F.
To clear entries from field, press
∗
43
∗
.
*44
Part. 1 Secondary Subs. Acct. No.
See *43 fir entries. To clear entries from field, press
∗
44
∗
.
*45
Part. 2 Primary Subs. Acct. No.
FA168CPS.
See *43 fir entries.
To clear entries from field, press
∗
45
∗
.
*46
Part. 2 Secondary Subs. Acct. No.
FA168CPS.
See *43 fir entries.
To clear entries from field, press
∗
46
∗
.
*47
Phone System Select
If Central Station Receiver is not on WATS
line: 0 = Pulse Dial; 1 = Tone Dial
If Central Station Receiver is on WATS line:
2 = Pulse Dial; 3 = Tone Dial
Select the type of telephone service.
*48
Report Format
(Primary/Secondary)
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
5 = ADEMCO Contact ID® 10-digit Format
6 = 4+2 ADEMCO EXPRESS
7 = ADEMCO Contact ID® 4-digit Format
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
Select report format for primary and secondary phone numbers.
*49
Split/Dual Reporting
0 = standard/backup reporting only
(all reports only to primary unless
unsuccessful, then attempts secondary)
1 - 5 (see table to right)
To Primary No.
To Secondary No.
1 = alarms, restore, cancel
others
2 = all except open/close, test
open/close, test
3 = alarms, restore, cancel
all
4 = all except open/close, test
all
5 = all
all
*50
Burglary Dialer Delay
0 = no dial delay
1 = 15 seconds; 2 = 30 secs; 3 = 45 secs
SIA-Compliant Controls:
Delay Time: 1 = 15 seconds; 2 = 30 seconds;
3 = 45 seconds
Delay Disable: 0 = use delay set in entry 1
1 = dial delay disabled for zones listed in
zone list 6 (use zone list 6 to enter those
zones that require dial delay to be
disabled; these zones ignore the setting
in entry 1)
Provides delay of burglary alarm report to the central station, which
allows time for the subscriber to avoid a false alarm transmission.
This delay does not apply to zone type 24 alarms (silent burglary) or
to 24-hour zone types 6, 7, and 8 (silent panic, audible alarm,
auxiliary alarm), which are always sent as soon as they occur.
UL: must be “0”
SIA-Compliant Controls:
UL: Dial delay plus entry delay must
not exceed one minute; use zone list 6 to disable dial delay from
appropriate zones, if necessary.
SIA Guidelines: delay must be minimum of 30 seconds
4-3
Содержание FA148CP Series
Страница 20: ...Installation Instructions 2 14...
Страница 48: ...Installation Instructions 5 8...
Страница 54: ...Installation Instructions 6 6...
Страница 58: ...Installation Instructions 8 2...
Страница 68: ...11 4...
Страница 76: ...Installation Instructions 13 4...
Страница 81: ...NOTES 14 5...
Страница 82: ...NOTES Installation Instructions 14 6...
Страница 83: ...NOTES 14 7...
Страница 84: ...NOTES Installation Instructions 14 8...
Страница 85: ...NOTES 14 9...
Страница 86: ...NOTES Installation Instructions 14 10...
Страница 87: ...NOTES 14 11...
Страница 88: ...NOTES Installation Instructions 14 12...