NOTICE 

When  Fireye  products  are  combined  with  equipment  manufactured  by  others  and/or  integrated  into 
systems designed or manufactured by others, the Fireye warranty, as stated in its General Terms and 
Conditions  of  Sale,  pertains  only  to  the  Fireye  products  and  not  to  any  other  equipment  or  to  the 
combined system or its overall performance. 

WARRANTIES 

FIREYE guarantees for one year from the date of installation or 18 months from date of manufacture of 
its products to replace, or, at its option, to repair any product or part thereof (except lamps, electronic 
tubes and photocells) which is found defective in material or workmanship or which otherwise fails to 
conform to the description of the product on the face of its sales order. 

THE FOREGOING IS IN LIEU 

OF  ALL  OTHER  WARRANTIES  AND  FIREYE  MAKES  NO  WARRANTY  OF 
MERCHANTABILITY  OR  ANY  OTHER  WARRANTY,  EXPRESS  OR  IMPLIED. 

Except  as 

specifically stated in these general terms and conditions of sale, remedies with respect to any product or 
part number manufactured or sold by Fireye shall be limited exclusively to the right to replacement or 
repair as above provided. In no event shall Fireye be liable for consequential or special damages of any 
nature that may arise in connection with such product or part. 

 

FIREYE

 

SF-200 

3 Manchester Road 

January 5, 2021 

Derry, New Hampshire 03038 USA 

Supersedes MAY 15, 2019 

fireye.com

 

Содержание SureFire II SP32-NG-FD

Страница 1: ...or LPG gas is SP 48 PG FD xxx where xxx is the insertion length L from 0 5 to 3 0 metres see Appendix 1 the pilot capacity vs gas pressure graphs for Natural gas and Propane For other Fuel gas types...

Страница 2: ...and should be ordered separately SP 32 FD pilot principle of use gas is supplied through the inlet 1 2 BSP to the gas head and to the gas tube and orifice stabilizer assembly Gas exits the main nozzle...

Страница 3: ...n left to be welded to the burner plate Pilot fixing inside the mounting tube as in p 7 1 There are two lengths A available 150 and 600 mm FIGURE 3 Gas pilot type SP 32 NG PG FD with examples of elect...

Страница 4: ...2 BSP inner thread Operating temperature max continuous 300 C orifice stabilizer end of gas and air tube 500 C Igniter rod reference length range L 0 5 3 0 m longer upon request Pilot weight P N SP 3...

Страница 5: ...S IN OPERATION ALWAYS KEEP THE PROPER AIRFLOW OF PILOT COMBUSTION COOLING AIR 7 1 MOUNTING TUBE The mounting tube if used should be attached to the burner plate using bolts or welding see Fig 2 If it...

Страница 6: ...ign of the main burner If an existing pilot has to be replaced the insertion length and pilot tip position should be the same In case of any doubts the position of the pilot should be consulted with t...

Страница 7: ...the air tube may start to glow it starts to glow at 400 500 C as the main flame burns inside the igniter Further opening of the air valve should stabilize the flame outside the air tube This will sto...

Страница 8: ...absence of the flame after trial for ignition the valves are closed and electrical igniter is switched off i Eventual repeating of trial for ignition sequence depends on the application Details of seq...

Страница 9: ...ilot does not operate correctly check the following a All manual gas valves on gas supply line were open and there is gas available b All valves in the supply line are functioning properly c The prese...

Страница 10: ...allation operation maintenance of igniter contrary to the instructions in the user manual unauthorized igniter modifications or repairs made by unauthorized personnel use of components or spare parts...

Страница 11: ...Natural Gas or Propane Gas Forced Draught 3 0 m insertion length The Table 2 below shows Part Numbers of gas igniter mounting tubes and spare parts Table 2 SureFire II Pilot Mounting Tubes Spare Part...

Страница 12: ...12 2021 Carrier APPENDIX No 1 The Pilot capacity vs gas pressure graphs standard version Remark The real measured capacity may differ by 5 depending on a particular pilot and measurement conditions...

Страница 13: ...ndustrial heaters shows position of SP 32 and SP 48 Gas Igniter operating as a continuous pilot on a sample main burner with gas spuds and central oil or gas gun vertical mounting The pilot air tube t...

Страница 14: ...biogas and especially refinery gas Refinery Off Gas needs additional engineering and testing because their gas compositions and calorific values are different than these of NG PG and LPG taken for gas...

Страница 15: ...35 315 cubic foot ft3 Air flow rate 1 cubic meter hour m3 h x 0 589 standard cubic foot min SCFM Weight 1 kilogram kg x 2 2046 pound lb Pressure 1 kilopascal kPa x 6 895 pound square inch gauge psig...

Страница 16: ...ls which is found defective in material or workmanship or which otherwise fails to conform to the description of the product on the face of its sales order THE FOREGOING IS IN LIEU OF ALL OTHER WARRAN...