Main Battery: Indicates the current battery output voltage. When running directly off the main
adapter the voltage will be between 12.5 and 12.9V. When the battery voltage falls below an accept-
able level (11.5V) to maintain optimum performance the 'LOW BATT' indicator LED will light.
Options: This indicates the options fitted to the instrument.
Ranges: This indicates the measurement range capability of the individual cells., i.e. CO 0-2000
ppm.
Gains: This indicates the working gain settings for the individual cells.
System Faults: This indicates any faults that the system will detect automatically.