6.3
POSITIONING
CLEARANCE REQUIREMENTS
This unit must be installed in accordance with the clearances shown on the rating label which is adhered to the
unit.
CLEARANCES
Combustible construction Noncombustible construction
Back
8 “ (200 mm)
2 ” (50 mm)
Right Side
0"
0"
Left Side
0"
0"
"Suitable for installation on combustible floors"
There are no particular prescriptions regarding side distances from other appliances, however it is advisable to
leave enough space (20/30 “ : 50/70 cm) in case of maintenance and/or repairs.
The appliance must stand level.
Small differences in level can be eliminated by screwing or
unscrewing the adjustable feet.
A significantly uneven or sloping stance can affect the
operation of the appliance adversely.
Adjust the bottom foot on each leg to overcome an uneven floor.
If the appliance is equipped with casters (optional), leveling must be ensured by the floor. If
the floor is not level, it must be made such with thicknesses in correspondence of the wheels.
The surface and the inclination of the shims must be such as not to affect the stability of the
machine.
After positioning remove the bars under the frame.
It is advisable to keep the bars so that they are available for subsequent movements.