8
Installation
(for qualified installers only)
Travis Industries
9 3 5 0 8 1 0 9
1 8 0 5 0 1
Clearances
•
When installed, walls in front of the fireplace must be a minimum 3-1/2" to the side of the faceplate.
•
Fireplace must be placed so that no combustibles are within, or can swing within 36" of the front of the
fireplace (e.g. drapes, doors)
•
Fireplace must be placed so the vents below and above the glass do not become blocked
Vertical Standoff
•
The vertical standoff above the fireplace must be erected prior to installation. See the illustration
below for instructions.
The vertical standoff is
shipped swiveled down.
Rotate the standoff
upwards into place.
5/16" Nutdriver
Secure the standoff
with the four screws.
These lifting
handles may be
removed once
the fireplace is
in place.
7/16" Wrench
Nail or screw the
fireplace to the
floor through the
holes on these
brackets.