
3 4
Finalizing the Installation
(for qualified installers only)
Travis Industries
9 3 5 0 8 1 0 9
1 8 0 5 0 1
Adjust the front air shutter if necessary.
Front Burner (front)
The front burner rarely requires adjustment.
The front burner flames are used to make
the rock wool glow, and do not rise more
than an inch off of the burner tube. If the
flames are sooty, follow the instructions for
opening the front burner air shutter.
Adjusting the Front Burner
Turn the heater off and let it cool completely. Remove the glass and logs. Locate
the front burner air shutter, loosen the lock screw holding the shutter in place, and
rotate the air shutter to a more open position. Replace the components and re-
evaluate the front burner flame.
Phillips
Screwdriver
Factory Setting:
1/16" open for NG
1/8" open for LP
The front air shutter rotates
to allow more air into the
front burner tube.
Front
Burner
Tube
Rear
Burner
Tube
!
If the vent configuration is installed incorrectly the vent may cause the flames inside the fireplace to lift
or "ghost" Ð a dangerous situation. Inspect the flames after installation to insure proper performance.
If the vent configuration is correct, yet the flames are lifting or ghosting, shut off gas to the fireplace
and contact the dealer for information on remedying the problem.
!
This fireplace has been tested at altitudes up to 8,000 feet. In this testing we have found that the
fireplace, with its standard orifice, burns correctly with just an air shutter adjustment. If local codes
require resizing the orifice, in the U.S.A. refer to ANSI 223.1, Appendix P, in Canada B-149.1 or B-
149.2
!
Failure to properly adjust the air shutter may lead to improper combustion and a
safety hazard. Consult your dealer or installer if you suspect an improperly
adjusted air shutter.
The flames should burn right off
the top of the burner ports (if they
are too blue, adjust the air control).
If the flames are lifting, yet the
vent configuration is correct,
contact your dealer.
Burner Tube
Burner Ports
(holes)
If the flames are ghosting, yet the
vent configuration is correct,
contact your dealer.