4 8
Optional Equipment
(for qualified installers only)
Travis Industries
9 3 5 0 8 1 0 9
1 8 0 5 0 1
5
Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice. The
propane conversion kit includes a .016Ó (labeled LP 16) or .011Ó (labeled LP 11) pilot orifice. The
.016Ó orifice is preferred because it allows for greater pilot adjustment.
VIEW FROM THE REAR
Remove the pilot
hood assembly by
unscrewing the two
attachment screws.
Pilot Orifice
LP (Propane) Orifices
Pull the pilot orifice
retainer and pilot orifice
upwards to remove.
Pilot Orifice
Retainer
Phillips
Screwdriver
Pilot Hood
Assembly
1
1
P
L
Orifice Identification:
1
6
P
L
(preferred)
NG (Natural Gas) Orifices
1
8
N
2
1
N
(preferred)
6
Replace the pilot shield (see step Ò4Ó above)
7
Replace the front and main burner (see step Ò2Ó above)
8
Adjust the front air shutter to a 1/8Ó opening.
Adjusting the Front Burner
Turn the heater off and let it cool completely. Remove the glass and logs. Locate
the front burner air shutter, loosen the lock screw holding the shutter in place, and
rotate the air shutter to a more open position. Replace the components and re-
evaluate the front burner flame.
Phillips
Screwdriver
Factory Setting:
1/16" open for NG
1/8" open for LP
This air shutter rotates to
allow more air into the front
burner tube.
Front
Burner
Tube
Rear
Burner
Tube
9
Install the logs and embers.
1 0
Replace glass and face.