FIREBIRD TWIN TIMER KIT.
Central Heating Timer.
Power on
'Fixed'.
Manual Switch.
Power on
to timer.
Power
off.
13
14
11
10
16
15
14
13
12
9
5
8
7
6
6
8
9
7
5
3
4
24
2 2
1
1
8
1
9
2
0
2
0
1
7
1
8
16
1
7
15
1
9
10
11
12
22
22
2
1
4
3
2
2
2
1
24
1
23
23
Domestic Hot Water Timer.
OPTIONAL TWIN TIMERS KIT
Firebird Enviromax Condensing Range
2
7
HOUSEHOLDER
Timer Switch
Pos. A
Constant
Timer Switch
Pos. B
Timed
Timer Switch
Pos. C
Off
PROGRAMMING GUIDE
SETTING UP
The outer dial should be set to
the current time. Rotate the dial
slowly in clockwise direction,
until the correct hour is aligned
with the arrow head printed on
the dial. Note that the outer dial
is printed with the 24 hour clock -
8:00 a.m. = 8 on the dial.
8:00 p.m. = 20 on the dial.
Do not attempt to rotate the dial
in an anti-clockwise direction.
Central Heating Control
The control panel is designed for simplicity of use and is
equipped with adjustable thermostat dial, optional
time controls and limit thermostat reset button as
shown above. It also has a built in system pressure
gauge which is connected to the boiler and heating
system water at the safety valve.
When replacing make sure that each thermostat
pocket receives correct phial by marking and noting
carefully each phial and its correct pocket.
MANUAL SWITCH
Manual switch operation: The manual switch will
provide Fixed On / Fixed Off / Auto control, thereby
allowing manual control of the switched output
without disrupting the timed (tappet) settings. Please
refer to the illustration above.
The slide switch can be set in one of the three positions
available ‘on’ and ‘off’ are fixed selections - the timer will
remain in the on or off condition until you next use the
manual switch to change the setting.‘auto’ is the normal
position for the switch, allowing control to be governed
by the tappet settings - in accordance with
‘programming switching times’ above
PROGRAMMING SWITCHING TIMES
Set all tappets between the on and off times required,
to the outer edge of the dial (see figure 1). E.g. to set on
at 8:00 a.m. - Off at 1:00 p.m. push tappets between dial
numbers 8 and 13 to outer edge of dial. Set any other
required switching times in a similar manner.