figure 1
Set at Max 80˚C
Set at Mid 70˚C
Set at Min 60˚C
Firebird Enviromax Condensing Range
2
5
HOUSEHOLDER
(ALL MODELS)
The boiler is factory fitted with a burner control box
lockout safety feature which operates automatically if a
fault occurs in the burners operation. Should this occur,
the light on the front of the burner - See Burner Section
Pg. 56 or Boiler Photo - will illuminate and its cause must
be investigated. This could be caused by:
A.
An interruption in the fuel supply.
(Eg. empty oil supply tank)
B.
An electrical supply fault.
C.
A fault with the burner or its safety control system.
D.
The failure of a component. (Eg. photo cell)
E.
Worn or dirty oil nozzle.
Before attempting to restart the boiler the front panel and
the burner cover should be removed and a visual check
made for any obvious problems such as oil leaks, loose
connections etc.
ENSURE OIL TANK CONTAINS CORRECT GRADE FUEL.
CLASS C2 KEROSENE
TO RESTART THE BOILER
1.
Press reset button See Burner Section Pg. 56 or
Boiler Photo
2.
Ensure that the boiler thermostat, time switch
(if fitted) and any external controls connected to the
boiler are set to call for heat.
3.
Check that the oil supply valves are open and that
there is sufficient oil in the tank.
4.
Check that the burner lockout light is unlit and with
the ‘mains ON’ the boiler will be ready to commence
its start sequence.
HEATPAC/SYSTEMPAC/SLIMLINE
Te
m
pe
r
atu
r
e Co
n
t
r
ol
BURNER
Lock-out
r
e-set butto
n
High Li
m
it
r
e-set butto
n
Bu
rn
e
r
Plug
Enviromax Heatpac, Systempac
and Slimline Heatpac
Operating Procedure
(All outputs)
TO START THE BOILER FOLLOW THIS SEQUENCE:
Turn on fuel supply.
Switch on power supply to boiler.
Turn timer control (If Fitted) to ‘ON’.
Set the boiler thermostat to the required
temperature (figure 1 pg. 5). The boiler thermostat
controls the boiler operation by automatically
maintaining the required boiler water temperature
output. Safe operation is also maintained by the
burner control system which provides the required
ignition and shut off sequence. If the optional timer
control is fitted this will automatically switch the
boiler off and on when heat is required.
THE BOILER CAN BE TURNED OFF BY
ANY OF THE FOLLOWING MEANS:
Turn the timer control (if fitted) to OFF.
Turn OFF the mains electrical supply to the boiler.
Burner Lockout
Thermostat Control