Firebird Enviromax Condensing Range
3
33
3.5 - HEAT PAC
ENVIROMAX
Combi Pac
System Pac
Heat Pac / Slimline Heatpac
Boiler Model
C20/26
C35
C20/26
C35
C44
C20/26
C35
C44/58
C73
Max Heat Output
Kw
20/26
35
20 / 26
35
44
20/26
35
44 / 58
73
Btu/h (‘000)
68/89
119
68 / 89
119
150
68/89
119
150 / 198
249
CONNECTIONS
Heating Flow
22 mm
28 mm
22 mm
28 mm
1
1
/
2
” Bsp.
1” Bsp.
1” Bsp.
1
1
/
2
” Bsp
1
1
/
2
” Bsp.
Heating Return
22 mm
28 mm
1” Bsp.
1” Bsp.
1
1
/
2
” Bsp.
1” Bsp.
1” Bsp.
1
1
/
2
” Bsp.
1
1
/
2
” Bsp.
Mains Cold Feed (Copper)
15 mm
15 mm
15 mm
15 mm
15 mm
Hot Water Delivery (Copper)
15 mm
15 mm
Drain Off Cock
1
/
2
”
Bsp
.
1
/
2
”
Bsp
.
1
/
2
”
Bsp
.
1
/
2
”
Bsp
.
1
/
2
”
Bsp
.
1
/
2
”
Bsp
.
1
/
2
”
Bsp
.
1
/
2
”
Bsp
.
1
/
2
”
Bsp
.
Safety Pressure Relief
valve outlet (Copper)
15 mm
15 mm
15 mm
15 mm
15 mm
Condense Drain Off Connection.
White Cased
3
/
4
”
Bsp
. Female
3
/
4
”
Bsp
. Female
3
/
4
”
Bsp
. Female
Heat Pac & Popular B.H.
22 mm PLASTIC
22 mm PLASTIC
22 mm PLASTIC
Circulating Pump (Grundfos)
25/60
25/60
25/60
25/60
25/80
Domestic Hot Water Plate
Heat Exchanger
25plate
31plate
Boiler integral Expansion
12 litres
12 litres
12 litres
12 litres
18 litres
Vessel Normal Capacity pre-charged to 1 bar.
pre-charged to 1 bar.
WATER CONTENT
Water Content Boiler
24
24
24
24
45
24
24
43.5
54
Water Content Primary Tank
(Litres)
40
40
D.H.W. GUIDE PERFORMANCE
C20/26 C35
120 litre at 40˚C
Δ
t. Litres per minute
14 / 16
20
FLUE (Indoor Boilers)
TEMPERATURE CONTROL
Boiler Central Heating Control
60˚C - 80˚C+- 3˚C
60˚C - 80˚C+- 3˚C
60˚C - 80˚C +- 3˚C
Boiler Safety Limit
110˚C +- 3˚C
110˚C +- 3˚C
110˚C +- 3˚C
Tank (DHW)- Fixed
78˚C +- 3˚C
Early Alert - Fixed
87˚C +- 3˚C
Over-run - Fixed
93˚C +- 3˚C
87˚C +- 3˚C
87˚C +- 3˚C (Heatpac & Kitchen only)
FROST THERMOSTAT FITTED
TO ALL HEAT PAC MODELS
HEATING SYSTEM (SEALED)
Fit in accordance with BS 7074
Part 1, BS 5449, OFTEC Standards, etc
Max. Operating Pressure
2.5 Bar
2.5 Bar
Max. System Pressure cold
1.5 Bar
1.5 Bar
Min. System Pressure cold
0.5 Bar + 0.3 Bar
0.5 Bar + 0.3 Bar
Boiler Test Pressure
4.5 Bar
4.5 Bar
4.5 Bar
Safety Valve Operating
Pressure Gauge
0 to 4 Bar
0 to 4 Bar
0 to 4 Bar
MAINS WATER SUPPLY
Limescale excess: When over 150/200 ppm. Fit appropriate scale reducer.
Pressure Max
5 bar Maximum Operating Pressure (Tested to 10 bar) (Fit pressure reducing valve as necessary)
Min
1 bar min. For user Comfort reduce pressure at tap to between 1 and 5 Bar.
WATER SIDE RESISTANCE
Flow Rate To Give A Nominal Output At 10k Differential
Flow Rate Measured
(Kg h
-1
)
2874.24
Waterside Resistance
(mbar)
0.18
Flow Rate To Give A Nominal Output At 20k Differential
Flow Rate Measured
(Kg h
-1
)
1522.92
Waterside Resistance
(mbar)
0.19
Pressure Jet Oil Burners
RIELLO RDB 2.2 up to C35 & RIELLO RDB 4.2 up to C58 - C73
Fuel
C2 Kerosene
Electrical Supply
230v. AC 50Hz To be fused at 5amp.
BOILER SAFETY LIMIT, FROST AND OVER-RUN THERMOSTATS FITTED ON ALL HEAT PAC MODELS
Содержание Enviromax Combi C20
Страница 2: ......
Страница 29: ...Firebird Enviromax Condensing Range 3 27 3 3 COMBI PLUMBING PARTS...
Страница 33: ...Firebird Enviromax Condensing Range 3 31 3 4 SYSTEM PLUMBING PARTS...