6.2 - POSITIONING THE BOILER
Ensure that adequate clearance is available for making the water and flue connections.
As the boiler is serviced from the front, no headroom clearance is necessary but a
clearance of 750mm must be available at the front of the boiler.
No special hearth is required as the boiler is fully insulated, but the floor must be
level and capable of supporting the weight of the boiler and its water content.
Sound levels must also be a consideration. Whilst Firebird Enviromax boilers are one of the quietest boilers on
the market, some householders are particularly sensitive and the following points should be considered:
1. Tiled surfaces in a small room will amplify noise - particularly if the wall construction is hollow.
2. If a conventional flue passes through a bedroom it is capable of transmitting noise.
3. Low level balanced flue terminals can produce exhaust noise on the outside terminal
and this should be considered when siting near adjacent property.
4. The Firebird Balanced Flue Kit has been specifically designed for Firebird’s indoor boilers.
The use of third party low level flue kits is not recommended and will affect its warranty.
5. The Siting of the boiler should take into account the disposal of condensate products.
• It is recommended that a suitable corrosion inhibitor is added to the heating system.
• New and existing systems should be treated with chemical cleaner and properly flushed before
the boiler is fitted and corrosion inhibitor added.
• In areas of hard water a suitable descaler would also be required.