15
STATUS
STROBE/PAD
ACTIVITY
POWER
GREEN
SMOKE
RED
FAULT
AMBER
CO
RED
ACTION
NEEDED
Unit fault
Illuminated
(providing Strobe is
plugged into mains)
Flashes rapidly
Contact technical
support
Network fault
Double flash every
1 sec
Ensure every
alarm and WiSafe
2 device is fitted
correctly and
working
Not Learned in
Illuminated
Follow learn in
procedure
Powering up
Strobe Unit will
chirp with beep
sequence
Double flash (not
repeated)
Double flash (not
repeated)
Double flash (not
repeated)
None required
WHAT TO DO IF YOUR
STROBE AND VIBRATING PAD GOES INTO ALARM
CAUTION:
In all circumstances assume your Strobe and
Vibrating Alert is responding to a real alarm situation
that has been triggered by either a smoke alarm or
carbon monoxide alarm.
The type of incident triggering the Strobe and
Vibrating Pad to go into alarm is indicated on the
Strobe:
Smoke Alert
The Smoke (red) LED will flash
Carbon Monoxide Alert
The CO (red) LED will flash
Smoke and CO Alert
The Smoke LED (red) will flash