UNPLUGGING FROM THE  

MAINS/POWER CUT

The way in which the Strobe and Pad alerts a warning 

is  the  same  for  both  alarm  types,  i.e.  the  Strobe  will 

flash and the Pad will vibrate in exactly the same way, 

irrespective  of  whether  the  alarm  is  triggered  by  a 

smoke alarm or a CO alarm.
If both smoke and CO alarms are in “alarm” mode, only 

the smoke LED will flash.

NOTE:

  The  Strobe  will  stop  flashing,  the  red  LED  will 

cease to flash and the Vibrating Pad will stop vibrating 

when  the  alarm  sending  the  signal  has  been  reset  or 

has stopped if the danger is no longer present. 
Only  reset  an  alarm  if  you  are  certain  there  is  no 

imminent danger from Fire or Carbon Monoxide.
Locate Feature
When the network is in alarm mode, pressing the test 

button on any unit in the network will silence all other 

alarms in the network, for a period of 2 minutes, except 

the alarm that has sensed smoke or carbon monoxide.  

This will enable the instigating alarm to be identified/

located.  If necessary, the instigating alarm can then be 

silenced.

The Strobe and Pad is designed to be mains powered.  

The  internal  rechargeable  battery  will  still  provide 

power  if  the  mains  is  disconnected.    A  fully  charged 

battery  will  allow  the  Strobe  and  Pad  to  continue  to 

operate for three days.  NB: Only use the battery supplied 

in the pack or a genuine FireAngel replacement.  Other 

rechargeable batteries may damage the equipment or 

create a safety hazard.

WARNING:

  When the mains power is disconnected, 

the green power LED will no longer illuminate and the 

amber (fault) LED will double flash every 5 seconds.

Plug the Strobe back into the mains as soon as possible 

to recharge the battery and maintain operation.
If  the  amber  LED  is  flashing  once  every  5  seconds 

when  the  green  power  LED  is  off  then  URGENTLY 

restore power to unit as battery status is very low, and 

may fail to operate in an alarm situation.

NOTE:

 Once the Strobe is plugged back into the mains, 

the amber (fault) LED will continue to flash once every 

5 seconds until the battery has fully recharged.

Содержание W2-SVP-630

Страница 1: ...roduct may be purchased from Connevans Limited secure online store at www DeafEquipment co uk DeafEquipment co uk Offering you choice Helping you choose Connevans info Solutions to improve the quality of life ...

Страница 2: ...User Manual COMBINED STROBE VIBRATING PAD W2 SVP 630 Please read me as I could save your life Please retain this user manual for future reference ...

Страница 3: ...Keeping you safe from fire and carbon monoxide For a full range of smoke alarms and carbon monoxide alarms visit www fireangel co uk ...

Страница 4: ...OR CO ALARM 6 TESTING THE WI SAFE 2 STROBE AND VIBRATING PAD WITH SMOKE CO ALARMS 7 POSITIONING 8 INSTALLING THE STROBE 10 LIMITATIONS 11 OPERATION 12 UNPLUGGING FROM THE MAINS POWER CUT 13 PRODUCT INDICATORS LEDS 14 WHAT TO DO IF YOUR STROBE AND VIBRATING PAD GOES INTO ALARM 15 WHAT TO DO IN THE EVENT OF A SMOKE ALARM TRIGGERING THE STROBE AND PAD 16 WHAT TO DO IN THE EVENT OF A CARBON MONOXIDE A...

Страница 5: ...Vibrating Pad will be triggered to alert someone who may not be able to hear the audible alarm The flashing strobe provides a visual warning for waking hours while the vibrating pad is designed to be placed under a pillow or a mattress and is suitable for waking an individual to alert them when a smoke alarm sounds If placed under a mattress ensure the thickness of the mattress does not cushion th...

Страница 6: ...Wi Safe 2 range purchased separately Wi Safe 2 Strobe and Vibrating Pad Pack contains 1 CP STROBE Strobe light with integrated control unit referred to as strobe 2 CP VPAD Vibrating pad to be placed under pillow or chair referred to as pad 3 AD DC12V05A AC mains adaptor 12v 0 5A rated output 4 B 450L Replaceable rechargeable 5 year life battery 5 Wall fixing screws NOTE TheStrobeandVibratingPadiso...

Страница 7: ...StrobeandVibratingPad NOTE Up to fifty Wi Safe 2 enabled Smoke alarms CO alarms and or Wi Safe 2 accessories can be interlinked learned in to a single network Ensure all smoke alarms and or CO alarms to be used are installed tested and working correctly as per the instructions in their respective user manuals It is possible to use the strobe independently For further details please contact Technic...

Страница 8: ...ire to red wire and clipping the connectors together You may hear the Strobe chirp as you do this 7 Plug the mains adaptor into a 230V socket and turn the power on The green power LED should illuminate 6 Plug the power cable in to the Strobe Route the wire through the wire guide fig3 3 Place the battery into the recess NB the battery cable needs to be positioned underneath the battery Place the ca...

Страница 9: ...isting Wi Safe 2 system You will use this product when adding the strobe into the network 2 Follow steps from point 2 above 3 After pressing this button the two Alarm red LEDs on the front of the unit will flash and then illuminate for 5 seconds 4 During this period while the red LEDs are illuminated press the test reset button on the Smoke or CO alarm to wirelessly interlink the two products The ...

Страница 10: ... unlearn the Strobe from the wireless network 1 Briefly push and release the learn button located in the circular hole in the back of the Strobe as shown fig 4 The two red alarm LEDs on the front of the Strobe will illuminate as you push the button 2 Push and hold the learn button a second time The red alarm LEDs will illuminate Hold the button until the red alarm LEDs extinguish 3 The red alarm L...

Страница 11: ...e alarms sound Both red alarm LEDs on the Strobe will flash for a short time This confirms that the units are wirelessly interlinked Weekly Testing It is recommended that a self test of all the units in your Wi Safe 2 network is carried out weekly TESTING THE WI SAFE 2 STROBE AND VIBRATING PAD WITH SMOKE CO ALARMS Testing the network from the Smoke Alarm or CO alarm Briefly press the test button o...

Страница 12: ...CO within sufficient time to alert you of the danger and provide adequate time for your escape In order to maximise your level of safety always test your Strobe and Vibrating Pad and all alarms in the Wi Safe 2 network system every week to ensure the whole system is in full working order and that the wireless interlink RF between the alarms and ancillary products has not been compromised NOTE The ...

Страница 13: ...below 5 C or rise above 40 C Anywhere where the units can easily be knocked or damaged It is important that if you install additional Strobes and Vibrating Pads you test each of these upon installation to check they are learned in to the rest of the network Wireless Range The wireless range of Wi Safe 2 products is over 200 metres in clear air clear line of sight However it is recommended not to e...

Страница 14: ...ing In the pack you will find two screws and two screw anchors Push the screw anchors if needed into the drill holes and secure the screw leaving the heads protruding so that the face of the head is 5mm away from the wall Now hook the Strobe onto the screws see below If placing the Strobe on a table instead of mounting on the wall make sure it cannot be easily knocked or slide off The green Power ...

Страница 15: ...Vibrating Pad is not compatible with products from the original Wi Safe product range The Strobe and Vibrating Pad will not operate in isolation with non Wi Safe 2 Alarms or any alarms made by other manufacturers The separate units making up the Strobe and Vibrating Pad cannot be interchanged with those of other manufacturers and an attempt to do this may render the whole system unsafe Do not conn...

Страница 16: ...is will enable the instigating alarm to be identified located If necessary the instigating alarm can then be silenced The Strobe and Pad is designed to be mains powered The internal rechargeable battery will still provide power if the mains is disconnected A fully charged battery will allow the Strobe and Pad to continue to operateforthreedays NB Onlyusethebatterysupplied in the pack or a genuine ...

Страница 17: ...ugged into mains Flashing once per second Reconnect vibrating pad to strobe Mains not connected and battery capacity low Strobe will chirp Flashing once every 5 secs URGENTLY restore power to unit as battery status is very low Alarm mode Smoke Strobe flashing pad vibrating Illuminated providing Strobe is plugged into mains Flashing Alarm CO Open windows and evacuate property Alarm mode CO Strobe f...

Страница 18: ...th beep sequence Double flash not repeated Double flash not repeated Double flash not repeated None required WHAT TO DO IF YOUR STROBE AND VIBRATING PAD GOES INTO ALARM CAUTION In all circumstances assume your Strobe and Vibrating Alert is responding to a real alarm situation that has been triggered by either a smoke alarm or carbon monoxide alarm The type of incident triggering the Strobe and Vib...

Страница 19: ...a cloth wet if possible Take short shallow breaths Keep doors and windows closed Open them only if you have to in order to escape Meet at your planned meeting place after leaving the house Carry out a head count Call the fire service on 999 as soon as possible from outside your house If possible use a neighbour s phone or call box rather than a mobile phone as the location can be traced from the n...

Страница 20: ...M What to do during an alarm Keep calm and open the doors and windows to ventilate the property Stop using all fuel burning appliances and ensure if possible that they are turned off Evacuate the property leaving the doors and windows open Ring your gas or other fuel supplier on their emergency number keep the number in a prominent place Do not re enter the property until the alarm has stopped Whe...

Страница 21: ... your Wi Safe 2 Strobe and Vibrating Pad is not working correctly and you are unable to resolve the problem after consulting the Troubleshooting section please contact Technical Support The battery provided has been chosen specifically for this application but will need to be replaced every 5 years under normal operating conditions If during normal operation i e connected to the mains supply for a...

Страница 22: ...cal Support on 0800 141 2561 The power green LED is illuminated and the Fault amber LED is also continuously lit The strobe unit is not interlinked learned in to the rest of the network If you have learned in the unit and this is happening regularly call Technical Support on 0800 141 2561 The Strobe and Pad does not respond to a smoke or CO alarm that is being tested Check that the alarm and the s...

Страница 23: ...date of purchase Sprue Safety Products Ltd at its discretion agrees to replace the unit free of charge The warranty on any replacement W2 SVP 630 will last for the remainder of the period of the original warranty in respect of the product originally purchased that is from the date of original purchase and not from the date of receipt of the replacement product Sprue Safety Products Ltd reserves th...

Страница 24: ...unding devices For more details visit www sprue com breach of any expressed or implied warranty Except to the extent prohibited by applicable law any implied warranty of merchantability or fitness for a particular purpose is limited in duration for 5 five years This warranty does not affect your statutory rights Except for death or personal injury Sprue Safety Products Ltd shall not be liable for ...

Страница 25: ...users dial 18001 0800 141 2561 EIRE dial 1 800 523171 Email technicalsupport fireangel co uk Web www fireangel co uk W2 SVP 630 Sprue Safety Products Ltd Vanguard Centre Sir William Lyons Road Coventry CV4 7EZ UK A Sprue Safety Products Brand GN2237 R2 ...

Отзывы: