9
Illustrations showing Completed Installations
Operation
Fire Feature Start Up
1. Prior to turning appliance on visually inspect fire feature to ensure debris such as leaves or other
combustible material has not collected inside the feature which could burn and emit embers once the
fire feature is turned on. Also ensure any person standing close to the fire feature is aware you will be
turning the fire feature on prior to actually turning it on.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance and to replace
any part of the control system and any gas control which has been under water.
WARNING
HOT – DO NOT TOUCH - SEVERE BURNS MAY RESULT - CLOTHING IGNITION MAY RESULT
-
CAREFULLY SUPERVISE children in same area as the appliance.
-
Alert children and adults to hazards of high temperatures.
-
Clothing or other flammable materials should not be hung from the appliance or placed on or near the
appliance.
WARNING
The appliance should be inspected before use and at least annually by a qualified service technician.
Any guard or protective device removed for servicing must be replaced prior to operation.
Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
Pilot Burner
Assembly
Battery
Pack
Gas
Line
Illustration of Properly Installed AWEIS
(Natural Gas)
Natural Gas Orifice
Fire Ring / Burner
(Holes Facing Up)
Pilot Burner
Assembly
Burner Pan
Battery
Pack
Drain Hole
Switch
Illustration of Properly Installed AWEIS
(Propane)
Gas
Line
Ignition
Control Box
Air Mixer
Drain Hole
Coupling
Fire Ring / Burner
(Holes Facing Up)
Burner Pan
Drain Hole
Drain Hole
Ignition
Control Box
Switch