4
Gas Requirements
Fuel Type – Before making gas connections ensure appliance being installed is compatible with the
available gas type. Check the label on the appliance to confirm appliance gas type requirement.
Gas Pressure – Proper input gas pressures are required for optimum appliance performance.
Gas Pressure Requirements
Electrical Requirements
The Battery Powered All Weather Electronic Ignition System operates on 3 AA batteries
which are installed inside a Weatherproof Battery Pack that is included with the system.
Recommended Replacement Batteries: Energizer AA Ultimate Lithium
Pressure
Natural Gas
Propane
Minimum
3.5” W.C. / 1/8 psi
8.0” W.C. / 1/3 psi
Nominal
7.0” W.C. / ¼ psi
11.0” W.C. / 1/3 psi
Maximum
14.0” W.C. / ½ psi
14.0” W.C. / ½ psi
Clearances
WARNING – FIRE RISK
8 ft.
36 in.
2 in.
Clearance from Combustibles
Main Burner Clearances
Min. 6” Clearance
Max. 3” Below
Top of Bowl