Install a manual shut-off valve in the gas line in an easily accessible location outside the cooktop. Be sure you know
how and where to shut off the gas supply to the cooktop. Install the electrical outlet 12″ below the
countertop.
ELECTRICAL CONNECTION:
This cooktop features pilotless electric ignition for energy savings and reliability. It operates on a 120 volt, 60 Hz
power supply. A separate circuit, protected by a 15 amp time delay fuse or circuit breaker, is required.
A properly-grounded 3-prong receptacle should be located within reach of the cooktop’s four-foot power cord.
IMPORTANT: (Please read carefully). FOR PERSON SAFETY, THIS APPLIANCE MUST BE
PROPERLY
GROUNDED.
The power cord of this appliance is equipped with a three-prong (grounding) plug which mates with a
standard
three-prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance.
The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure
the receptacle is properly grounded and has correct polarity.
Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and obligation of the
customer to have it replaced with a properly grounded three-prong wall receptacle.
Do Not, Under Any Circumstances, Cut Or Remove The Third (Ground) Prong From The Power
Cord.
Do not use an extension cord.