16
LOADING PROCEDURE
Take care not to lose pens, lighters, etc. from shirt pockets, or
drop pieces of paper or plastic bags into the tank, as these might
plug the slurry system. Failure to comply could result in death or serious injury. Failure to
comply could also result in product or property damage.
1. With the pump clutch disengaged (turned off), hydraulic system turned off and the agitator
control lever in the NEUTRAL position, start the engine and allow it to warm up. See
STARTING PROCEDURE section.
2. After the engine has warmed up, turn on the hydraulic system by flipping the hydraulics
toggle switch [with the blue icon
(
)
] to the
ON
(
)
position (all the way up). The switch
will center itself, which is the ON position.
3. Start filling unit with water from one of the water sources as listed below. When water
reaches the top of agitator shaft, move agitator control to full REVERSE position.
Tank can be filled by using one of the sources of water as follows:
A. Water from any stream or pond using a fill pump. When filling from a pond or
stream, be sure to use a suction strainer to filter out contaminants that could
damage the pump and unit.
B. Any pressure source, eg. fire hydrant. An optional air gap fill port is available for
this unit but it is necessary to consult with local authorities before using a water
main, in order to abide by all local ordinances.
C. Water tanker.
4. Piping System Cleanout Procedure (Purging Line):
A. Remove discharge nozzle and coupler gasket from remote valve coupler at the
end of the discharge hose.
B. Aim discharge hose into an open area away from any persons, obstructions, or
high voltage power lines.
C. Open discharge and remote valves and close recirculation valve.
T30
Gallons (Liters)
Inches (centimeters)
from Top
Inches (centimeters)
from Bottom
300
(1136)
6.25 (15.9)
32.75 (83.2)
275
(1041)
8.75 (22.2)
30.25 (76.8)
250
(946)
11.0 (27.9)
28.0 (71.1)
225
(852)
13.5 (34.3)
25.5 (64.8)
200
(757)
16.0 (40.6)
23.0 (58.4)
175
(662)
18.25 (46.4)
20.75 (52.7)
150
(568)
20.5 (52.1)
18.5 (47.0)
125
(473)
23.0 (58.4)
16.0 (40.6)
100
(379)
25.25 (64.1)
13.75 (34.9)
75
(284)
27.75 (70.5)
11.25 (28.6)
50
(189)
30.75 (78.1)
8.25 (21.0)
25
(95)
34.0 (86.4)
5.0 (12.7)
TOP
BOTTOM
300
150
250
200
100
75
50
25
275
225
175
125
TANK CAPACITY CHART