Once done, a popup window will appear indicating the update is successful. Click 

OK

 

to proceed. The Ingress software has to be synced with all relevant devices in order 
for the changes to take effect. A small window will appear at the bottom left corner of 
the screen once any changes are made. 

Click on the underlined blue sentence to sync the terminals. Any changes made will 
appear in the 

Synchronize

 Device Settings window. Check/Tick the changes needed 

to be synced to the terminals. Click 

Start Synchronize

 once the selections are made. 

Another popup window will appear, displaying the changes made at the particular 
doors affected. Click 

Start Synchronize

 once everything is confirmed.

Once synchronization is complete, click 

Close

 to proceed. Go to 

Other

 tab and click on 

Reboot Device

. A window will pop up, seeking confirmation on whether to restart the 

device.  Click 

Yes

 and the IP address for the terminal has been successfully changed. 

Содержание H2i

Страница 1: ...Simple Fingerprint Door Access Time Attendance System User Guide H2i s u p p o r t f i n g e r t e c c o m H2i ...

Страница 2: ...ress Online Activation Installation and Setup of Ingress Connecting Terminals to Ingress Using USB to Download Upload Data Communication Key 18 22 CHAPTER 4 MANAGING USER Enrolling Administrator Card Registration of Administrator Card Enrolling User Cards Verifying Card for Attendance or Access Deleting Card User or Fingerprint User Operations with USB Numeric Keyboard Using the UBS Numeric Keybor...

Страница 3: ...N u m L o c k H o m e P g U p P g D n D e l E n te r In s E n d B a c k s p a c e 7 4 1 0 8 5 2 9 6 3 Diod Back Plate Thick Back Plate Thin Rubber Padding Keypad 1 GETTING STARTED Viewing the User Guide in the Internet The User Guide is available in the package when you purchase FingerTec H2i The user guide is also published online at fingertec com and user fingertec com Choose the language you pr...

Страница 4: ...llment Template Form Warranty Card Activating H2i Connect all the cables correctly at their specific points and turn on the power sup ply The H2i terminal does not have an on off button Registering H2i Make sure that you register your H2i s warranty with us at www fingertec com ver2 english e_main html ...

Страница 5: ...the terminal an administrator card is needed However the H2i also has the option of using a nu meric USB keypad as an administrative tool As usual more advanced management of FingerTec H2i can be done via the included software in the package H2i Overview Item Function LED Indicating status of terminal and result of verification Green Terminal is in standby mode or verify users successfully Red Ter...

Страница 6: ...g accessed by unauthorized individual s ADMINISTRATOR CARD Registration of an administrator card to the system is important to control access into H2i After registration of the administration card is done nobody can do en rollment deletion or resetting on the H2i without the administration card TAMPER SWITCH H2i comes with a tamper switch located at the rear of the terminal During instal lation th...

Страница 7: ...set to 1 after the process The administrator card information will be deleted from the memory and you will need to reenroll it However user information and trans action logs will still remain in the memory RESETTING TO DEFAULT FACTORY SETTINGS WITHOUT AN ADMINISTRATOR CARD Green LED light blinks Detach the terminal from the wall Release tamper switch This might trigger a connected alarm Wait 30 se...

Страница 8: ...Installations FingerTec terminals offer several connections for power and communications In stallations of FingerTec time attendance terminals are simple than installation for door access functions Mount On Wall Attach the back plate on the wall securely and attach the terminal to the back plate when mounting it on the wall ...

Страница 9: ... BEEP GND WIEGAND INPUT CONNECTION PORT 3rd party controller with 26 bits wiegand output WD0 WD1 WIEGAND OUTPUT CONNECTION PORT 3rd party controller with 26 bits wiegand intput TCP IP PORT Ethernet Connection RX RX RS485 Data Converter 485A 485B 485A 485B 485A 485B RX RX RS485 Data Converter Communications Connection points for power and communication are available on top of the termi nals Refer t...

Страница 10: ...2V Power Supply 12V GND POWER SUPPLY PORT 485 485 GND BUT SEN NO COM NC AL AL ACCESS CONNECTION PORT Release button Door sensor DC12V Power Supply 12V GND POWER SUPPLY PORT 1 3 B D EM lock NO Emergency break glass NO Key switch NO GND BUT NO1 COM1 NC1 Optional to use with Diode Door lock system GND BUT NO1 COM1 NC1 Optional to use with Diode Door lock system FOR NC NORMALLY CLOSE DOOR LOCK SYSTEM ...

Страница 11: ...se T and 100Base TX TCP IP for Network Connection Linking the terminals to multiple computers using TCP IP requires Ethernet 10 100Base T Straight Thru Cable or whips The cable works with both 10Base T and 100Base TX connecting a network interface card to a hub or network outlet POWER SUPPLY PORT Insert the Power Adapter point to this port for power RS485 WIEGAND INPUT CONNECTION PORT RS485 Single...

Страница 12: ...of Ingress Install Ingress in a PC that fulifills Ingress minimum requirements Refer to http www fingertec com customer download postsales SUM Ingress E pdf for the In gress user guide online Setup Wizard will require you to do online activation be fore connection establish between Ingress and terminals Connecting Terminal to Ingress THE FIRST TIME CONNECTION When connecting the Terminal to the In...

Страница 13: ... by adding another terminal or Add to add only one terminal To add multiple devices at one go click Scan Device and Scan IP Address range can be set to search for devices The bigger the range of IP address the longer time needed to scan for devices Devices found will be displayed on the screen Select the preferred devices and click Add Selected Device to add them and a window contain ing the setti...

Страница 14: ...14 CONTENTS Once the device has been added a pop up window will appear indicating that the device has been successfully added Click Ok to proceed ...

Страница 15: ...ress via Ingress are as below Go to Doors tab and click on Add Door Once the door is added click on Add Device at the Doors tab Check Tick the terminal s to be added to the specific door Click OK Double click on the device At the Network tab click Edit Change the desired IP address at the IP Address URL column When done click Save to confirm the changes made ...

Страница 16: ...ges made will appear in the Synchronize Device Settings window Check Tick the changes needed to be synced to the terminals Click Start Synchronize once the selections are made Another popup window will appear displaying the changes made at the particular doors affected Click Start Synchronize once everything is confirmed Once synchronization is complete click Close to proceed Go to Other tab and c...

Страница 17: ...sten to the command from the terminal The terminal will name each operation in sequence as shown below You need to wave administrator card at the induction area to confirm the relevant command 1 To download transaction logs from terminal to USB flash disk Green LED blinks Download transaction logs Please wave your adminis trator card for confirmation Wave administrator card at the card induction a...

Страница 18: ... Administrator card Find the administrator card to proceed or you need to reset the terminal in order to enroll with a new administrator card Enrolling Cards Users Green LED blinks Wave administrator card at the card induction area Register user Please press your finger or wave your card Wave card at the card induction area Terminal reads card and creates a new user ID e g User number 2 Registrati...

Страница 19: ...ing Card Fingerprint or Both for Attendance or Access Please check that you have configured the correct verification method s i e Fin gerprint only Card only Fingerprint or Card Fingerprint and Card in the terminal through the TCMS V2 software FINGERPRINT ONLY Green LED blinks Press your finger on scanner Beep once Thank you Green LED blinks Verification is successful Attendance record is captured...

Страница 20: ...ete User Please press your finger or wave your card The user has been deleted Repeat steps above to de lete the other users Wave administrator card to end process System returns to verification mode Remark 1 Each user is entitled to have one card only Therefore when the card user is deleted the user ID is completely deleted from the terminal 2 Each user can enroll a maximum of 10 fingerprints unde...

Страница 21: ...assword 4 to 6 digits for example 456789 Press ENTER The operation is successful System returns to verification mode Enrolling Users You can enroll users with fingerprints or cards without using an administrator card Use the keyboard to carry out enrollment operation in the terminal Plug keyboard to the terminal The LED of keyboard lit up The Green LED blinks Insert password via keyboard Password ...

Страница 22: ...troublesome Now you may consider using the USB numeric keypad to ease the job Plug keyboard to the terminal The LED of keyboard lit up The Green LED blinks Insert password via keyboard Password confirmation is successful Press button 4 Press ENTER Please enter the IP address Insert IP address using keyboard example 198 168 1 2 Press ENTER key operation is successful Please enter the Subnet Mask In...

Страница 23: ...y complete and accurate information Information in this document is subject to change without prior notice DISCLAIMER No person should rely on the contents of this publication without first obtaining advice from a qualified professional person The company expressly disclaims all and any liability and responsibility to any terminal or user of this book in respect of anything and of the consequences...