![Fiem CIP CIP 28 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/fiem/cip-cip-28/cip-cip-28_manual-for-use_2287982015.webp)
Egg health and hygiene
To maximise fertility and to avoid contamination during the incubation period, please follow the directions below when
collecting eggs:
- Collect the eggs daily to avoid contamination or loss from breakage or damage,caused by hot or cold temperatures
(winter and summer periods).
- Before filling the incubator with eggs, clean them using a clean wet soft cloth;
- Clean hands before and after egg collection with anti-batcerial soap.
- LOAD EGGS STORED NOT MORE THAN 7- 8 DAYS AND NOT LESS THAN 3 DAYS FROM LAYING.
- BEFORE INCUBATION, THE EGGS MUST BE STORED IN A SPECIFIC EGG-BASKET (IN VERTICAL POSITION
WITH THE AIR-SPACE FACED UPWARDS) WITH TEMPERATURE BETWEEN 14
- 16 °C.
- Do not mark the eggs with felt-tip pens – use only pencil.
TECHNICAL CHARACTERISTICS
POWER SUPPLY
V/Hz
220 - 230 / 50 - 60
POWER CONSUMPTION
Watt.
130 / 60
SIZES
mm
380 x 390 x 250h (CIP CIP 28)
455 x 445 x 270h (CIP CIP 40)
WEIGHT
Kg
9,5 (CIP CIP 28)
13,00 (CIP CIP 40)
EGGS CAPACITY
Hen - Duck
28 / 40
Pheasant
36 / 52
Partridge – Quail – Red leg
52 / 64
Turkey – Wild duck
24 / 35
Goose
9 / 18
Take note that the above capacities are refered to standard values of medium size eggs.
INCUBATION PERIOD OF THE DIFFERENT SPECIES
SPECIE
DAYS
SPECIE
DAYS
HEN
21
PEKIN DUCK
27-28
QUAIL
16-17
WILD DUCK
25-26
TURKEY
28
BARBARY DUCK
34-35
GUINEA FOWL
26
RED LEG
23-24
PARTRIDGE
23-24
PHEASANT
24-25
GOOSE
30
BOB WHITE
22-23
CARE AND MAINTENANCE
In order to achieve the best operation and longest life of the machine, follow the following precautions:
- do not expose the machine to outdoor elements
- do not place machine in hot, wet or cold rooms;
- avoid bad handling during moving that can cause breakages inside the machine and affect its working;
- disconnect the power plug before cleaning the machine;
- do not accidentally pull out the power cable when moving the machine.
IMPORTANT:
take out the plug from the socket by holding the plug and not the power cable; use only a mains power
socket or surge-protected extension lead.
- for cleaning and disinfection please follow the advice as follows
HOW TO CLEAN THE INCUBATOR
For a good hygiene during the incubation, it is recommended to clean the machine before and after its use;
use a wet cloth on the machine with a light disinfectant, do not use solvents that can damage the machine cabinet;
clean the base of the machine and the water basins with a normal domestic detergent.
aDviCe:
after cleaning the machine, please keep it working without eggs and basins for at least two hours (with
the door semi-closed), in order to dry the humidity which has accumulated during the incubation period... This will
ensure the correct machine operation for the next use.
15
Содержание CIP CIP 28
Страница 2: ...2 ...