2 Technical Indicators
Copyright © Fibocom Wireless Inc.
19
Test Item
Test Condition
Low temperature operating test
Temperature at -30℃±3°C, lasting for 24 hours in
operating state
High-temperature operating test
Temperature at +75℃±3°C, lasting for 24 hours in
operating state
Vibration test
Carry out vibration test according to the following
requirements.
Frequency: 5 Hz to 20 Hz; Random vibration ASD
(acceleration spectral density): 0.96 m
2
/s
3
Frequency: 20 Hz to 500 Hz; Random vibration ASD
(acceleration spectral density): 0.96 m
2
/s
3
(at 20 Hz).
For other frequencies, the random vibration ASD is
-3 dB/octave.
Connector lifespan test
30 times cable insertion and removal to the RF
antenna interface
After the test items are tested, the module can be powered on, the function is normal,
and the performance meets the standard.
2.7
ESD Indicators
The design of LC116-LA module needs to consider ESD protection. The module pins have
limited anti-static ability, and the key input/output signal interfaces must be handled with
ESD measures. Reasonable structural design and PCB layout design can ensure that the
metal shield shell is completely grounded, so as to improve the anti-static capability of the
equipment. The following table describes the ESD withstand voltage of module pins
under the condition of temperature of 25℃ and humidity of 45%.
The ESD allowable discharge range of the module is as follows (temperature: 25°C,
relative humidity: 40%):
Содержание LC116-LA