2 Technical Indicators
Copyright © Fibocom Wireless Inc.
18
2.5
Application Environment
Table 14. Environment indicators
Parameter
Minimum Value (℃) Typical Value (℃) Maximum Value (℃)
Operating temperature -30
25
75
Extended temperature -40
-
85
Storage temperature
-40
-
95
In the limited operating temperature range, some RF indexes may exceed the standard. It
is suggested that the temperature control measures should be considered in the
application end under the harsh environment. At the same time, it is suggested that the
module application terminal should be stored at a certain temperature. Beyond this range,
the module may not work properly or be damaged.
2.6
Reliability Indicators
To improve the reliability and stability of the product, the module has been tested for
reliability as shown in the table below.
Table 15. Reliability test
Test Item
Test Condition
Low temperature storage test
Temperature -40℃±3°C, 24 hours in shutdown state
High temperature storage test
Tempe85℃±3°C, 24 hours in shutdown state
Temperature shock test
In shutdown state, 0.5 hour at -40°C and +85°C
ambient temperatures respectively, the temperature
conversion time is less than 3 minutes, and the
temperature conversion is repeated for 24 times.
High temperature and humidity
test
Temperature at +85℃±3°C, humidity at 85% RH,
lasting for 24 hours in shutdown state