12
operatInG tHe DeVIce
3. Verify correctness of connection.
4. Power the device.
5. Add the device to the Z-Wave network.
6. Change values of parameters:
• Connected to IN1: change parameter 20 to 4
• Connected to IN2: change parameter 21 to 4
4.7: Connection with binary sensor
You connect normally opened or normally binary sensors to IN1/IN2
terminals.
1. Disconnect power.
2. Connect with the diagram below:
GND 9-30V
GND
IN1
IN2
P
1
2
Diagram 7: Example connection with 2 binary sensors
(1,2 – binary sensor)
3. Verify correctness of connection.
4. Power the device.
5. Add the device to the Z-Wave network.
6. Change values of parameters:
• Connected to IN1:
»
Normally close: change parameter 20 to 0
»
Normally open: change parameter 20 to 1
• Connected to IN2:
»
Normally close: change parameter 21 to 0
»
Normally open: change parameter 21 to 1