Ratchet Relay

 G4Q

Ratchet Relay

G4Q

Unique Ratchet Mechanism Assures Positive 
Alternate Transfer/Switching Operation

• Each contact in the double-pole contact mechanism performs 

alternate make-brake operation at each pulse input and is thus 
ideal for alternate operation or transfer/switching operation of a 
motor.

• Positive operation is assured due to the unique ratchet mecha-

nism.

• Satisfies dielectric strength of 2,000 VAC.

• Low power consumption.

(AC: approx. 6.4 VA; DC: approx. 3.9 W)

Ordering Information

Open Models

Plug-in Models

Model Number Legend

1. Contact Form

2:

DPDT

2. Contact Type

1:

Single

3. Enclosure Construction

1:

No casing

2:

Casing

4. Terminal Shape

A:

Solder

S:

Plug-in

Item

DPDT

Rated voltage (V)

Model

Basic model

6 VAC

G4Q-211A

12 VAC

24 VAC

50 VAC

100/(110) VAC

200/(220) VAC

6 VDC

12 VDC

24 VDC

48 VDC

100 VDC

200 VDC

Item

DPDT

Rated voltage (V)

Model

Basic model

6 VAC

G4Q-212S

12 VAC

24 VAC

50 VAC

100/(110) VAC

200/(220) VAC

6 VDC

12 VDC

24 VDC

48 VDC

100 VDC

200 VDC

Rated coil voltage

Note:

      When ordering, add the rated coil voltage (listed in 

Specifications

) to the model number.

      Example: G4Q-211A, 24 VAC

G4Q-

@@@@

1    2   3    4

Содержание G4Q

Страница 1: ... 6 4 VA DC approx 3 9 W Ordering Information Open Models Plug in Models Model Number Legend 1 Contact Form 2 DPDT 2 Contact Type 1 Single 3 Enclosure Construction 1 No casing 2 Casing 4 Terminal Shape A Solder S Plug in Item DPDT Rated voltage V Model Basic model 6 VAC G4Q 211A 12 VAC 24 VAC 50 VAC 100 110 VAC 200 220 VAC 6 VDC 12 VDC 24 VDC 48 VDC 100 VDC 200 VDC Item DPDT Rated voltage V Model B...

Страница 2: ...erminal Solder terminal 8PFA1 PL08 Item Current mA Resistance Ω Must operate Must release Max voltage Power consumption Rated voltage V 50 Hz 60 Hz of rated voltage Initial Rated AC 6 1 233 1 067 0 54 80 max 10 min 110 max Approx 13 5 VA Approx 6 4 VA 12 614 531 2 24 24 307 266 8 7 50 148 128 42 7 100 110 74 64 73 5 160 200 220 37 32 36 8 671 Item Current mA Resistance Ω Must operate Must release ...

Страница 3: ...ntact 1 000 VAC 50 60 Hz for 1 min between con tacts of same polarity 2 000 VAC between contacts of different polarities Vibration resistance Destruction 10 to 55 to 10 Hz 0 75 mm single amplitude 1 5 mm double amplitude Malfunction 10 to 55 to 10 Hz 0 5 mm single amplitude 1 0 mm double amplitude Shock resistance Destruction 500 m s2 Malfunction 100 m s2 Endurance Mechanical 5 000 000 operations ...

Страница 4: ...ature rise C Contact carry current 5 A Contact with no carry current Ambient temperature C Malfunctioning Shock Not energized Energized Unit m s2 Number of samples 5 Measurement conditions Impose a shock of 100 m s2 in the X Y and Z directions three times each with the Relay energized and not energized to check the shock values that cause the Relay to malfunction Shock direction 100 ms min Contact...

Страница 5: ... Relay The width of the Relay is 63 5 mm and the width of the Socket is 51 mm Mounting Mount the Relay so that the coil faces upward and the cam faces downwards with the mounting plate secured vertically Do not change the cam angle Make sure that Relay terminals are free of flux or any other foreign substance before soldering the Relay terminals 92 5 max 71 5 max 30 5 63 5 max 80 max Plug in Termi...

Отзывы: