ID
Parameter
Instance-
s
Data
type
Access
1)
Arraysize
20022
Configuration of voltage monitoring load
supply PL
–
0: load voltage monitoring inactive
–
1: load voltage monitoring active, with
suppression of diagnostics at switch-
off (factory setting)
–
2: load voltage monitoring active
1
UINT8
rw
–
20052
Behaviour in error state (communication
fault)
–
0: reset outputs (factory setting)
–
1: maintain status
1
UINT8
rw
–
20085
Measured value temperature AP-ASIC [°C]
1
INT16
ro
–
20087
Current measured value of logic supply PS
[mV]
1
UINT16
ro
–
20088
Current measured value of load supply PL
[mV]
1
UINT16
ro
–
20093
Hardware version
1
UINT8
ro
–
1) ro = read only; rw = read write
Tab. 9 Parameter
10
Diagnostics and fault clearance
10.1
Diagnostic messages
ID hex (dec)
Message
Description
Undervoltage of the logic supply PS 24 V DC was detec-
ted.
Remedy
–
Check logic supply PS.
02
|
01
|
0016
(33619990)
Undervoltage in logic
supply PS 24 V DC
Diagnost-
ic status
Warning
Error
Overvoltage in the logic supply PS 24 V DC detected.
Remedy
–
Check logic supply PS.
02
|
01
|
0017
(33619991)
Overvoltage in logic
supply PS 24 V DC
Diagnost-
ic status
Error
Diagnostics and fault clearance
9
Festo — VAEM-L1-S-...-AP — 2019-06
Содержание VAEM-L1-S Series
Страница 1: ...8099702 VAEM L1 S AP Electrical interface 8099702 2019 06 8099704 Instructions Operat ing ...
Страница 2: ...Translation of the original instructions 2 Festo VAEM L1 S AP 2019 06 ...
Страница 13: ...12 Technical data Technical data 13 Festo VAEM L1 S AP 2019 06 ...
Страница 17: ......