6.2.2
AS-Interface addresses
Prior to commissioning, assign the MS6(N)-SV-...-E-ASIS a slave address that is not safety-oriented and
an address of a safety-oriented slave.
The modules or slaves that have been addressed should always be carefully labelled.
Address assignment
The following tables show the assignment of the data bits to the inputs and outputs.
Cyclical digital data
Inputs
Description
n.c.
n.c.
DI1
DI0
0
0
Pneumatic status exhaust
0
1
Pneumatic status pressurize
1
0
Minor error; pneumatic limits exceeded or fallen below
1
1
Major error; defect uncovered in the hardware/software
Tab. 5
Cyclic digital data inputs
Outputs
Description
DO3
DO2 n.c.
n.c.
x
x
Not used
Tab. 6
Cyclical digital data outputs
Cyclical analogue values
O15 … O0
Description
xxxxxxxxxxxxxxxx
Pressure p1
Tab. 7
Cyclical analogue values outputs
O15 … O0
Description
xxxxxxxxxxxxxxxx
Pressure p2
Tab. 8
Cyclical analogue values outputs