Festo — MS6(N)-SV-...-E-10V24 — 2021-11e
Technical data
33
Runtime performance
t1
>
5 ms:
Level of EN2/EN1 must be HIGH for min. 5 ms (debounce time/input filter/stabi-
lisation time).
t2
<
= 75 ms:
maximum permissible delay time between EN1 and EN2. If exceeded, the product
is not pressurised and an error message is output.
t3
>
= 15 ms:
Level of EN2/EN1 must be LOW for min. 15 ms (debounce time/input filter/stabi-
lisation time).
t4 = 2 ms:
maximum internal time delay caused by the program sequence.
tp1
}
2:
Pressurisation
>
300 ms
tp2
}
3:
Exhausting
>
1 s
Tab. 14: Runtime performance