16
Festo — MS6(N)-SV-...-E-10V24 — 2021-11e
Product overview
The following requirements apply to the manager:
–
The specifications for mounting and the operating conditions in these operating instructions must
be observed.
–
For use in higher categories (2 to 4), the requirements of EN ISO 13849, e.g. CCF, must be consid-
ered.
–
The basic and proven safety principles of EN ISO 13849-2 relating to implementation and operation
of the component must be satisfied.
–
When using this product in machines or systems subject to specific C standards, the requirements
specified in these standards must be observed.
–
Before using the product, a risk assessment in accordance with EN ISO 12100 as specified in the EC
Machinery Directive 2006/42/EG, Annex I, Paragraph 1 and 1.1.2 is required.
–
The user is responsible for coordinating all applicable safety regulations and rules with the compe-
tent authority and for compliance with regulations and rules.
Failures due to a common cause (Common Cause Failure – CCF)
The following measures ensure that common cause failures are avoided:
–
Compliance with the permissible values for vibration and shock stress
–
Compliance with the temperature range
–
Compliance with compressed air quality as specified in the technical data, in particular avoiding
flash rust particles (such as caused by servicing work) as well as compliance with the residual oil
content of max. 0.1 mg/m
3
when using ester-containing oils (which may, for example, be contained
in the compressor oil)
–
Compliance with the maximum operating pressure, if necessary with a pressure-relief valve
–
Clogging of the silencer must be avoided.
PFH
D
value
The PFH
D
value depends on the model of the product and the annual actuation rate (n