Timing: stop and resume end-to-end travel with press function (example "Mov
Out
" motion)
The diagram shows the stopping and resuming of the "Mov
Out
with press function" motion from the
"Stop
Out
" command to reaching the "Lim
Out
" end position with the status data in DIO and IO-Link
operation.
Stop task Stop
Out
–
Activation of the stop task DIO: digital input DI1 "Mov
In
" = 0 and DI2 "Mov
Out
" = 0
–
Activation of the stop task IO-Link: parameter 0x0029.1 = false and 0x0029.2 = false or
system parameter0x0002 (value 0xCA "Stop motion")
Motion task Start
Out
–
Activation of the motion task DIO: digital input DI2 "Mov
Out
" = 1 and DI1 "Mov
In
" = 0
–
Activation of the motion task IO-Link: parameter 0x0029.2 = true and 0x0029.1 = false or
system parameter 0x0002 (value 0xC9 "Move Out")
Drive system
55
Festo — EMCS-ST — 2020-04a