Timing: switch-off behaviour in the event of logic voltage failure
The diagram shows the switch-off behaviour of the EMCS-ST when the logic voltage fails or is discon-
nected.
1 [Power] Power ON (24 V DC)
2 [Logic] Power ON
è
OFF (24 V DC)
3 Power stage active (position controlled)
4 LED C/Q
Fig. 11 Switch-off behaviour in the event of logic voltage failure
Timing: switch-off behaviour in the event of load voltage failure
The diagram shows the switch-off behaviour of the EMCS-ST when the load voltage fails or is discon-
nected.
1 [Power] Power ON
è
OFF (24 V DC)
2 [Logic] Power ON (24 V DC)
3 Power stage active (position controlled)
4 LED C/Q
5 Error: load voltage undersupply or not con-
nected
Fig. 12 Switch-off behaviour in the event of load voltage failure