Festo CPX-P Скачать руководство пользователя страница 92

Subject to change – 2018/04

92

è

 Internet: www.festo.com/catalogue/...

Terminal CPX-P

Technical data – Pneumatic interface VMPA‐FB

Function

The pneumatic interface VMPA‐FB

establishes the electromechanical

connection between the CPX-P ter­

minal and the valve terminal MPA-S.

The signals from the bus node are for­

warded to the control electronics in

the electrical modules of the valve ter­

minal MPA-S via the integrated CPX-P

bus. The bus signal for activation of

the solenoid coils is converted in the

electronics module for max. 8 coils.

From a technical point of view, the

individual MPA pneumatic modules

each represent a separate electric

module with digital outputs. Valves,

which are galvanically isolated, can

be supplied with power via the

interlinking block CPX-GE-EV-V.

Applications

Interface to the valve terminal

MPA-S

Max. 128 solenoid coils

Features of the electronics module

of the valve terminal MPA-S can be

parameterised, for example status

of the solenoid coils in the event of

fieldbus communication being

interrupted (fail-safe), individual

channel diagnostics can be acti­

vated, condition monitoring can be

activated individually for each valve

The pneumatic interface receives

the voltage for the electronics and

the supply voltage for the valves

from the left-hand interlinking

block and feeds them through to

the electronics modules of the valve

terminal MPA-S

Electronics modules of the valve

terminal MPA-S:

– Undervoltage of valves

– Short circuit of valves

– Open load of valves

– Counter preset reached in

condition monitoring

General technical data

Type

VMPA-FB-EPL-G

VMPA-FB-EPL-E

Number of solenoid coils

128

Pilot air supply

Internal

External

Pilot air port 12/14

M7

Pneumatic connection 1

G

¼

G

¼

Operating pressure

[bar]

3 … 8

–0.9 … 10

Pilot pressure

[bar]

3 … 8

3 … 8

Nominal operating voltage

[V DC]

24

Protection class to EN 60529

IP65

Ambient temperature

[°C]

–5 … +50

Materials

Cover

PA

Housing

Die-cast aluminium

Product weight

[g]

Approx. 320

Содержание CPX-P

Страница 1: ...Modular electrical terminal CPX P...

Страница 2: ...outputs 2 4 way Analogue inputs and outputs with HART protocol Input modules for connecting NAMUR sensors IP65 or IP20 Wall or H rail mounting also on mobile units Conversions extensions are possible...

Страница 3: ...versal communication technology across all areas including operating level management level and field level in the production environment with protection to IP65 The following protocols are supported...

Страница 4: ...cks M12 4 pin Screw terminal and spring loaded terminal CPX modules for NAMUR sensors intrinsically safe circuits for ATEX applications PLC Fieldbus 1 2 3 4 5 6 6 1 Higher order controller 2 Non ATEX...

Страница 5: ...ssembled according to your order specifications and individually tested The finished valve terminal consists of the electrical peripherals including the desired actuation and the selected components f...

Страница 6: ...fieldbus parameters via DIL switch Display of fieldbus and peripheral equipment status via LED Remote unit CPX CEC Connection via Ethernet TCP IP or Sub D programming interface Setting of operating m...

Страница 7: ...for the entire system Additional power supply for outputs Connection accessories for 7 8 Individual linking with M6 screws individually expandable Digital inputs for connecting the sensors Digital out...

Страница 8: ...P20 Spring loaded terminal Screening concept Optional screening plate for con nection block with M12 connection technology Direct machine mounting connection block to IP65 IP67 M12 5POL Digital electr...

Страница 9: ...interlinking block Individual linking 86 System linking Different voltage values for supplying the modules Serial communication between the modules System supply 7 8 5 pin In addition to system linki...

Страница 10: ...linking blocks Combination of connection blocks and electronics modules for inputs and outputs Digital electronics modules For inputs For outputs For NAMUR sensors CPX 8DE CPX 8NDE CPX 16DE CPX 4DA CP...

Страница 11: ...livers pre assembled M8 M12 connecting cables NEBU modular system on request Tailored to the application Perfect fit Saves installation Combination of connection block and electrical connection techno...

Страница 12: ...ectable connection technology 1 CPX AB 8 M8X2 4POL Socket M8 4 pin 2 NEBU M8G4 Modular system for choice of connecting cables Socket M8 3 pin Socket M8 4 pin Socket M12 5 pin Open cable end 3 NEDY L2R...

Страница 13: ...Plug connector connecting cable Selectable connection technology 1 CPX P AB 4XM12 4POL 8DE N IS Socket M12 4 pin 3 NECU M S A12G4 IS Plug M12 4 pin 3 NECU S M12G4 IS Plug M12 4 pin 2 NEDU M12D4 M12T4...

Страница 14: ...sign per connection Version R with quick lock techno logy and metal thread for screening With two channels per connection the corresponding input signals can be easily connected via a T adapter and co...

Страница 15: ...ystem for all types of sensor actuator distributor 2x socket M8 3 pin 2x socket M8 4 pin 2x socket M12 5 pin 2x socket type A 2x socket type B 2x socket type C 2x socket plug pattern H 2x socket plug...

Страница 16: ...tion block Connection technology Plug connector connecting cable Selectable connection technology 1 CPX AB 8 KL 4POL Spring loaded terminals 32 pin 2 AK 8KL cover Electrical connection Connection bloc...

Страница 17: ...Plug connector connecting cable Selectable connection technology 1 CPX AB 1 SUB BU 25POL Socket Sub D 25 pin 2 SD SUB D ST25 Crimp contacts Electrical connection Connection block with quick connector...

Страница 18: ...for the underlying modules in combination with a suitable mounting plate provided by the user Protection against electrostatic discharge through the use of electrically conductive materials and the op...

Страница 19: ...lot nut with screws for joining the hood sections 5 Rail 6 Mounting bracket Technical data Weight Hood approx 500 g per 100 mm of length Mounting rail approx 550 g per 1 000 mm of length Side pieces a...

Страница 20: ...ill need the following mounting kit CPX CPA BG NRH This facilitates mounting of the CPX P terminal on H rails to EN 60715 An additional mounting kit is required for combination with valve terminals Wa...

Страница 21: ...ply for electronics plus sensors valves plus actuators Connection technology 7 8 Interlinking blocks Interlinking blocks represent the backbone of the CPX P terminal with all supply lines They provide...

Страница 22: ...nnected to output modules of the CPX P terminal Without power supply CPX M GE EV With additional power supply for outputs CPX M GE EV Z 7 8 5POL CPX M GE EV Z 7 8 5POL VL Connection technology 7 8 5 p...

Страница 23: ...puts and valves Open load detection for a missing solenoid coil Storage of the last 40 causes of errors with error start and error end The diagnostic messages can be read out via the bus interface in...

Страница 24: ...nges to the application are often required during commissioning The parameterisable characteristics of the CPX P modules mean that functions can be very easily changed by means of configuration softwa...

Страница 25: ...gured as counter 80 16 CPX P 8DE N IS 16 8 CPX P 8DE N IS inputs configured as counter 80 16 CPX 8DE 8 CPX 8NDE 8 CPX 16DE 16 CPX 4DA 4 CPX 8DA 8 CPX 4AE U I 4 x 16 CPX 2AA U I 2 x 16 CPX 4AE 4AA H V...

Страница 26: ...62818 Max no of modules1 Control block 1 Bus node 1 I O modules 9 Pneumatic interface 1 Max address capacity Inputs byte 64 Outputs byte 64 Internal cycle time ms 1 Configuration support Fieldbus spec...

Страница 27: ...ectronics only ms 10 Power supply connection 7 8 5 pin Fuse concept Per module with electronic fuses Tests Vibration test to DIN IEC 68 With wall mounting Severity level 2 With H rail mounting Severit...

Страница 28: ...Certificates If the component is subject to restrictions on usage in residential office or commercial environments or small businesses further measures to reduce the emitted interference may be necess...

Страница 29: ...wer supply for outputs 7 8 5 pin 550210 CPX M GE EV Z 7 8 5POL 7 8 5 pin for ATEX environment 8022158 CPX M GE EV Z 7 8 5POL VL Mounting accessories Screws for mounting the bus node connection block o...

Страница 30: ...g attachments for connecting several hood sections in series 200 mm 572258 CAFC X1 GAL 200 300 mm 572259 CAFC X1 GAL 300 User documentation CPX P System Manual German 526445 P BE CPX SYS DE English 52...

Страница 31: ...on commissioning and diagnostics of the MPA S pneumatic components Electronic components P BE CPX SYS System description installation and commissioning Overview of the design components and mode of op...

Страница 32: ...el oriented errors Condition monitoring preselection loading of counters activation of the channels to be monitored Display of the last 40 error occurrences with timestamp Identification of sporadic c...

Страница 33: ...agnostics Fast access to the diagnostic history and the modules with diagnostic messaging Display of the last 40 diagnostic messages with timestamp Display of the current diagnostic message for a modu...

Страница 34: ...th wall mounting Severity level 2 With H rail mounting Severity level 1 Materials Reinforced PA Dimensions W x H x D mm 81 x 137 x 28 Product weight g 150 Operating and environmental conditions Ambien...

Страница 35: ...3 Ordering data Designation Part No Type Operator unit Provides data polling configuration and diagnostic functions for CPX P terminals 529043 CPX MMI 1 Connecting cable Connecting cable M12 M12 spec...

Страница 36: ...ctly as a CPX FMT project Undocumented changes can subsequently be identified using the online offline comparison function On site tests such as the actuation of valves or the emulation of sensor feed...

Страница 37: ...rop feature You can insert and move modules 1 Module numbers from the graphic system overview 2 Catalogue for selecting required modules Module overview for a selected module Displays important module...

Страница 38: ...inal CPX P Technical data CPX Maintenance Tool Dimensions Download CAD data www festo com Adapter 1 Mini B 5P USB port 2 Plug M12x1 5 pin Ordering data Designation Part No Type CPX P Maintenance Tool...

Страница 39: ...in the input table of the controller In addition to cyclic data transmis sion acyclic communication is sup ported through explicit messaging which enables detailed device diagnostics and parameterisat...

Страница 40: ...channel oriented diagnostics by means of manufacturer specific diagnostic object Parameterisation Module and system parameterisation via configuration interface in plain text EDS Online in run or prog...

Страница 41: ...g Incoming 1 Blank Screened Connection to housing 2 Red 24 V DC bus 24 V DC supply for CAN interface 3 Black 0 V bus 0 V CAN interface 4 White CAN_H Received transmitted data high 5 Blue CAN_L Receive...

Страница 42: ...BA 2 M12 5POL Socket for Micro Style connection M12 18324 FBSD GD 9 5POL Plug for Micro Style connection M12 175380 FBS M12 5GS PG9 Open Style bus connection for 5 pin terminal strip 525634 FBA 1 SL 5...

Страница 43: ...n Part No Type User documentation User documentation for bus node CPX FB11 German 526421 P BE CPX FB11 DE English 526422 P BE CPX FB11 EN Spanish 526423 P BE CPX FB11 ES French 526424 P BE CPX FB11 FR...

Страница 44: ...to EN 50170 Volume 2 for cyclic I O exchange parameterisation and diagnostic functions DPV0 In addition to DPV0 acyclic commu nication to the advanced specification DPV1 is supported DPV1 provides ac...

Страница 45: ...t up parameterisation via configuration interface in plain text GSD Acyclic parameterisation via DPV1 Additional functions Storage of the last 40 errors with timestamp access via DPV1 8 bit system sta...

Страница 46: ...trol signal 5 DGND Data reference potential M5V 6 VP Supply voltage P5V 7 n c Not connected 8 RxD TxD N Received transmitted data N 9 n c Not connected Hous ing Screened Connection to housing Bus conn...

Страница 47: ...PX AB 2 M12 RK DP Socket M12x1 5 pin straight for self assembly of a connecting cable compatible with FBA 2 M12 5POL RK and CPX AB 2 M12 RK DP 1067905 NECU M B12G5 C2 PB Plug M12x1 5 pin straight for...

Страница 48: ...n Part No Type User documentation User documentation for bus node CPX FB13 German 526427 P BE CPX FB13 DE English 526428 P BE CPX FB13 EN Spanish 526429 P BE CPX FB13 ES French 526430 P BE CPX FB13 FR...

Страница 49: ...stic information configuration information etc can be transferred The Ethernet bandwidth is sufficient to transfer both data types real time and non real time in parallel The bus node features LEDs fo...

Страница 50: ...nal functions Start up parameterisation in plain text via fieldbus Fast startup FSU Channel oriented diagnostics via fieldbus Acyclic data access via fieldbus System status can be represented using pr...

Страница 51: ...1 Bus specific status LEDs 2 CPX P specific status LEDs 3 Fieldbus connection 4 pin socket M12 D coded 4 Transparent cover for DIL switch and memory card Pin allocation for the fieldbus interface Pin...

Страница 52: ...er for DIL switch and memory card 548757 CPX AK P Function block Memory card for PROFINET bus node 2 MB 568647 CPX SK 2 Screws Screws for attaching an inscription label holder to the bus node 12 piece...

Страница 53: ...pply for electronics mA Typically 75 Nominal operating voltage V DC 24 reverse polarity protected Permissible voltage fluctuations 25 Power failure buffering ms 20 Residual ripple Vss 0 4 Electrical i...

Страница 54: ...module CPX P 8DE N IS has additional safety measures for pos sible faults such as non resettable fuses to ensure safe operation as per the ignition protection type If the module is operated within th...

Страница 55: ...CPX P 8DE N CPX P 8DE N IS CPX P AB 4XM12 4POL 565706 n CPX P AB 2XKL 8POL 565704 n CPX P AB 4XM12 4POL 8DE N IS 565705 n CPX P AB 2XKL 8POL 8DE N IS 565703 n Pin allocation Connection block outputs C...

Страница 56: ...NECU L3G8 C1 IS1 Screw terminal Black 565710 NECU L3G8 C2 Gentian blue 565709 NECU L3G8 C2 IS1 Plug M12 4 pin Spring loaded terminal For cable 4 8 mm 575719 NECU M S A12G4 IS1 Screw terminal For cabl...

Страница 57: ...8DE CPX 8NDE Number of inputs 8 8 Max residual current of inputs per module A 1 0 7 Fuse protection Internal electronic fuse per module Intrinsic current consumption at operating voltage mA Typically...

Страница 58: ...OL 549367 n n Pin allocation Connection block inputs CPX 8DE and CPX 8NDE CPX AB 8 M8 3POL X1 1 24 VSEN x X1 3 0 VSEN x X1 4 Input x X5 1 24 VSEN x 4 X5 3 0 VSEN x 4 X5 4 Input x 4 X2 1 24 VSEN x 1 X2...

Страница 59: ...24 VSEN x 3 X4 1 0 VSEN x 3 X4 2 Input x 3 X4 3 FE X8 0 24 VSEN x 7 X8 1 0 VSEN x 7 X8 2 Input x 7 X8 3 FE CPX AB 1 SUB BU 25POL 1 Input x 2 Input x 1 3 Input x 2 4 Input x 3 5 24 VSEN x 1 6 0 VSEN x...

Страница 60: ...L Distributor Modular system for all types of sensor actuator distributor NEDY Internet nedy 1x plug connector M12 4 pin 2x socket M8 3 pin 8005311 NEDY L2R1 V1 M8G3 N M12G4 2x socket M12 5 pin 800531...

Страница 61: ...KL 4POL IP65 IP67 8 cable throughfeeds M9 1 cable throughfeed for multi pin plug 538219 AK 8KL Fittings kit 538220 VG K M9 Screening plate Screening plate for M12 connections 526184 CPX AB S 4 M12 Use...

Страница 62: ...al current of inputs per module A 1 8 Intrinsic current consumption at operating voltage mA Typically 15 Fuse protection Internal electronic fuse for each module Nominal operating voltage V DC 24 Oper...

Страница 63: ...2 4POL 541256 n CPX AB 8 KL 4POL 195708 n CPX AB 1 SUB BU 25POL 525676 n Pin allocation Connection block inputs CPX 16DE CPX AB 8 M8x2 4POL X1 1 24 VSEN X1 2 Input x 1 X1 3 0 VSEN X1 4 Input x X5 1 24...

Страница 64: ...0 VSEN X6 2 Input x 5 X6 3 FE X3 0 Input x 10 X3 1 24 VSEN X3 2 Input x 2 X3 3 FE X7 0 Input x 14 X7 1 0 VSEN X7 2 Input x 6 X7 3 FE X4 0 Input x 11 X4 1 24 VSEN X4 2 Input x 3 X4 3 FE X8 0 Input x 1...

Страница 65: ...8 S Sub D plug 25 pin 527522 SD SUB D ST25 Connecting cable For push in T connector 1x socket M8 3 pin 1x plug connector M8 3 pin 0 5 m 541346 NEBU M8G3 K 0 5 M8G3 1 0 m 541347 NEBU M8G3 K 1 M8G3 2 5...

Страница 66: ...ction and diagnostics through integrated electronic fuse protection General technical data Type CPX 4AE U I Voltage input Current input Number of analogue inputs 4 Max power supply per module A 0 7 Fu...

Страница 67: ...oothing Signal range per channel Wire break monitoring per channel Behaviour after short circuit Behaviour after overload at input Sensor supply active Protection class to EN 60529 Depending on connec...

Страница 68: ...CPX AB 4 M12X2 5POL R1 and CPX M AB 4 M12X2 5POL X1 1 24 VSEN X1 2 Input 0 X1 3 0 VSEN X1 4 Input 0 X1 5 FE2 X3 1 24 VSEN X3 2 Input 2 X3 3 0 VSEN X3 4 Input 2 X3 5 FE2 X2 1 24 VSEN X2 2 Input 1 X2 3...

Страница 69: ...tion block inputs CPX 4AE U I CPX AB 1 SUB BU 25POL 1 Input 0 2 Input 0 3 Input 1 4 Input 1 5 n c 6 n c 7 n c 8 n c 9 24 VSEN 10 24 VSEN 11 0 VSEN 12 0 VSEN 13 Screening1 14 Input 2 15 Input 2 16 Inpu...

Страница 70: ...AB 4 M12X2 5POL Plug Plug M12 5 pin PG7 for cable 4 6 mm 175487 SEA M12 5GS PG7 Sub D plug 25 pin 527522 SD SUB D ST25 Connecting cable Modular system for connecting cables NEBU Internet nebu Cover H...

Страница 71: ...load 4 channels can be connected in parallel 0 5 12 W lamp load 8 channels can be connected in parallel Fuse protection short circuit Internal electronic fuse for each channel Module current consumpt...

Страница 72: ...L 4POL 195708 n n CPX AB 1 SUB BU 25POL 525676 n n CPX AB 4 HAR 4POL 525636 n n CPX M AB 4 M12X2 5POL 549367 n n Pin allocation Connection block outputs CPX 4DA CPX 8DA CPX AB 8 M8 3POL X1 1 n c X1 3...

Страница 73: ...x 1 X1 3 0 VOUT X1 4 Output x X1 5 FE X3 1 n c X3 2 Output x 3 X3 3 0 VOUT X3 4 Output x 2 X3 5 FE X1 1 n c X1 2 Output x 1 X1 3 0 VOUT X1 4 Output x X1 5 FE X3 1 n c X3 2 Output x 5 X3 3 0 VOUT X3 4...

Страница 74: ...3 Output x 2 4 Output x 3 5 n c 6 0 VOUT 7 n c 8 0 VOUT 9 n c 10 n c 11 0 VOUT 12 0 VOUT 13 FE 14 Output x 4 15 Output x 5 16 Output x 6 17 Output x 7 18 n c 19 n c 20 n c 21 n c 22 0 VOUT 23 0 VOUT...

Страница 75: ...Y L2R1 V1 M8G3 N M8G4 1x plug M12 4 pin 2x socket M12 5 pin 8005311 NEDY L2R1 V1 M8G3 N M12G4 2x socket M8 3 pin 8005310 NEDY L2R1 V1 M12G5 N M12G4 Plug M8 3 pin Solderable 18696 SEA GS M8 Screw in 19...

Страница 76: ...KL Fittings kit for hood AK 8KL 538220 VG K M9 Cover cap for sealing unused connections 10 pieces For M8 connections 177672 ISK M8 For M12 connections 165592 ISK M12 Screening plate Screening plate fo...

Страница 77: ...c fuse protection General technical data Type CPX 2AA U I Voltage output Current output Number of analogue outputs 2 Max actuator supply per module A 2 8 Fuse protection Internal electronic fuse for a...

Страница 78: ...ort circuit monitoring actuator supply Short circuit monitoring analogue output Behaviour after short circuit actuator supply Data format Lower limit value full scale value Upper limit value full scal...

Страница 79: ...X1 3 FE X5 0 24 VOUT X5 1 0 VOUT X5 2 Output GND X5 3 FE X2 0 n c X2 1 n c X2 2 Output U0 X2 3 FE X6 0 n c X6 1 n c X6 2 Output U1 X6 3 FE X3 0 24 VOUT X3 1 0 VOUT X3 2 Output GDN X3 3 FE X7 0 24 VOUT...

Страница 80: ...G7 for cable 4 6 mm 175487 SEA M12 5GS PG7 Sub D plug 25 pin 527522 SD SUB D ST25 Connecting cable Modular system for all types of sensor actuator distributor NEDY Internet nedy Modular system for con...

Страница 81: ...fuse protection General technical data Type code CPX 4AE 4AA H Protocol HART Number of selectable analogue inputs outputs 4 Sensor type 0 20 mA 4 20 mA 4 20 mA with HART Operating voltage Nominal val...

Страница 82: ...Housing PA reinforced PC Note on materials RoHS compliant Operating and environmental conditions Ambient temperature C 5 50 Storage temperature C 20 70 Relative humidity 95 non condensing Corrosion r...

Страница 83: ...rror Combinations of bus nodes control blocks with HART input output module Bus node control block Part No Protocol HART input output module CPX 4EA 4AA H CPX FB13 195740 PROFIBUS n CPX FB33 548755 PR...

Страница 84: ...X4 2 0 V X4 3 Input x 3 X4 4 0 V X2 1 Output I1 X2 2 0 V X2 3 X2 4 0 V X4 1 Output I3 X4 2 0 V X4 3 X4 4 0 V CPX P AB 2XKL 8POL X1 1 24 VSEN x X1 2 0 V X1 3 Input x X1 4 0 V X2 1 24 VSEN x 2 X2 2 0 V...

Страница 85: ...cting cross section 0 2 2 5 mm2 565710 NECU L3G8 C2 Plug M12x1 4 pin straight A coded Insulation displacement connector Connecting cross section 0 25 0 5 mm2 525928 SEA GS HAR 4POL Screw terminal Conn...

Страница 86: ...minal 24 V DC supply voltage for inputs 24 V DC supply voltage for valves 24 V DC supply voltage for outputs General technical data Nominal operating voltage V DC 24 Protection class to EN 60529 Depen...

Страница 87: ...ck 5 pin 550208 CPX M GE EV S 7 8 5POL For ATEX environment 8022165 CPX M GE EV S 7 8 5POL VL 7 8 connection sockets Power supply socket 5 pin 543107 NECU G78G5 C2 Angled socket 5 pin open cable end 5...

Страница 88: ...rs and actuators individually Applications All voltages are fed through to the next module by means of interlinking blocks The connected electronics module for inputs outputs or bus node taps off the...

Страница 89: ...g data Designation Part No Type Interlinking block without supply Metal interlinking block 550206 CPX M GE EV Mounting accessories Screws for mounting the bus node connection block on an interlinking...

Страница 90: ...off specific areas of the sensors and actuators individually Applications 24 V DC supply voltage for outputs General technical data Nominal operating voltage V DC 24 Protection class to EN 60529 Depe...

Страница 91: ...al interlinking block 5 pin 550210 CPX M GE EV Z 7 8 5POL 5 pin For ATEX environment 8022158 CPX M GE EV Z 7 8 5POL VL 7 8 connection sockets Power supply socket 5 pin 543107 NECU G78G5 C2 Angled sock...

Страница 92: ...s module of the valve terminal MPA S can be parameterised for example status of the solenoid coils in the event of fieldbus communication being interrupted fail safe individual channel diagnostics can...

Страница 93: ...ings Ordering data Designation Part No Type Pneumatic interface Ducted exhaust air internal pilot air 552286 VMPA FB EPLM G Ducted exhaust air external pilot air 552285 VMPA FB EPLM E Flat plate silen...

Страница 94: ...onnection block CPX AB 8 KL 4POL 6 Connection block CPX AB 1 SUB BU 25POL 7 Connection block CPX P AB 4 2XKL 8POL 8 Connection block CPX P AB 4XM12 4POL 9 Right hand end plate aJ Mounting bracket for...

Страница 95: ...y plate aC Pressure sensor aD Proportional pressure regulator n Number of sub bases in a grid of 4 MPA1 or 2 MPA2 valves m Number of CPX P modules Type B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 C...

Страница 96: ...nal D coded For Ethernet 543109 NECU M S D12G4 C2 ET For cable 2 5 2 9 mm 570955 NECU S M12G4 P1 Q6 IS1 192008 SEA 4GS 7 2 5 For cable 2x3 mm or 2x5 mm 570956 NECU S M12G4 D IS1 For 2x cable 3 5 mm 18...

Страница 97: ...dy Modular system for connecting cables NEBU Internet nebu Push in T connector 1x plug M8 4 pin 2x socket M8 3 pin 8005312 NEDY L2R1 V1 M8G3 N M8G4 1x plug M12 4 pin 2x socket M8 3 pin 8005311 NEDY L2...

Страница 98: ...200 300 mm 572259 CAFC X1 GAL 300 Screws Screws for mounting the bus node connection block on an interlinking block Bus node plastic connection block 550219 CPX M M3x22 4x Bus node metal connection bl...

Страница 99: ...tch and memory card 548757 CPX AK P Cover for RJ45 connection 534496 AK Rj45 Cover cap for sealing unused connections 10 pieces For M8 connections 177672 ISK M8 For M12 connections 165592 ISK M12 Codi...