Subject to change – 2018/04
26
è
Internet: www.festo.com/catalogue/...
Terminal CPX-P
Technical data
-K-
Module width
50 mm
-H-
Note
The data given here apply to the
CPX-P system. If components that
conform to lower values are used in
the system, the specification for the
entire system is reduced to the
values of those components.
Example
Protection class IP65 applies only to
the fully assembled system with fitted
plugs or covers (which must also con
form to IP65). If components with a
lower protection class are used, the
protection level of the entire system is
reduced to the protection class of the
component with the lowest protection
level, for example CageClamp connec
tion block with IP20 protection.
General technical data
Module No.
562818
Max. no. of modules
1)
Control block
1
Bus node
1
I/O modules
9
Pneumatic interface
1
Max. address capacity
Inputs
[byte]
64
Outputs
[byte]
64
Internal cycle time
[ms]
1
Configuration support
Fieldbus-specific
LED displays
Bus node/control block
Up to 4 LEDs, bus-specific
4 LEDs, CPX-P-specific
PS = Power system
PL = Power load
SF = System fault
M = Modify parameter/forcing active
I/O modules
Min. one group diagnostic LED
Channel-oriented status and diagnostic LED, depending on module
Pneumatic interface
One group diagnostic LED
Valve status LED on valve
Diagnostics
Channel and module-oriented diagnostics for inputs/outputs and valves
Detection of module undervoltage for the different potential values
Storage of the last 40 errors with timestamp (acyclic access)
1)
A maximum of 11 modules in total can be combined.
(e.g. 1 control block + 9 I/O m 1 pneumatic interface, or 1 control block + 1 bus node + 8 I/O m 1 pneumatic interface)