Terminal CPX-P
Technical data – Operator unit CPX-MMI-1
General technical data
Type
CPX-MMI-1
Data interface
RS232 interface, 57.6 kBaud, M12 socket, 4-pin
Display component
LCD graphical display with background illumination (128 x 64 pixels)
Control elements
7 keys:
4 arrow keys and 3 function keys, touch-sensitive keypad
Electromagnetic compatibility
Interference emission tested to DIN EN 61000-6-4, industry
Interference immunity tested to DIN EN 61000-6-2, industry
Nominal operating voltage
[V DC]
24, supplied by the connected device
Operating voltage range
[V DC]
18 … 30
Current consumption
[mA]
50 … 60
Protection class to IEC 60529
IP65
Relative air humidity
[%]
90, non-condensing
Vibration resistance
Tested to DIN/IEC 68/EN 60068, Part 2-6
With wall mounting: Severity level 2
With H-rail mounting: Severity level 1
Shock resistance
Tested to DIN/IEC68/EN60068, Part 2-27
With wall mounting: Severity level 2
With H-rail mounting: Severity level 1
Materials
Reinforced PA
Dimensions (W x H x D)
[mm]
81 x 137 x 28
Product weight
[g]
150
Operating and environmental conditions
Ambient temperature
[°C]
0 … 50
CE marking (see declaration of conformity)
To EU EMC Directive
1)
To EU Explosion Protection Directive (ATEX)
ATEX category
Gas
II 3 G
Dust
II 3 D
Ex ignition protection type
Gas
Ex nA IIC T6 X Gc
Dust
Ex tc IIIC T60°C X Dc IP65
ATEX temperature rating
[°C]
–5 <= Ta <= +50
1)
For information about the applicability of the component see the manufacturer’s EC declaration of conformity at: www.festo.com/sp
è
Certificates.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.
-H-
Note
When operating device combinations
in hazardous areas, the lowest
common zone, temperature class and
ambient temperature of the
individual devices determine the
possible use of the entire module.
Connection and display components
2
3
1
4
1
Display (LCD display)
2
Function keys
3
Arrow keys
4
M12 interface