3. Input module CPX-P-8DE-N-...
3-50
Festo P.BE-CPX-P-EA-EN en 1209NH English
Error
no.
Error elimination
Error description
Handheld display
29
[Fault in parametrizing]
Fault in parametrisation
1)
Parameterisation implaus-
ible;
the channel continues to op-
erate with the old parameter
setting; the process status
refers to this parameter
status
•
Check the parameterisa-
tion measures conducted
and, if necessary, conduct
the parameterisation pro-
cess again with the correct
parameters (valid paramet-
ers
section 3.3.9).
55
[Invalid process value]
Invalid process value
1)2)
End of the counting range has
been reached; informative
(no error)
•
none; error message for in-
formation purposes
1)
The module registers the corresponding error depending on parameterisation.
2)
Standard CPX error with product-specific error description
3)
In operating mode B (counter) this message occurs upon reaching the respective limit value (also
refer to the parameter description in Tab. 3/32 and Tab. 3/33).
Tab. 3/40:
Error elimination
Содержание CPX-P-8DE-N Series
Страница 2: ......
Страница 34: ...1 Overview and connection technology 1 14 Festo P BE CPX P EA EN en 1209NH English...
Страница 35: ...Mounting and dismantling 2 1 Festo P BE CPX P EA EN en 1209NH English Chapter 2 Mounting and dismantling...
Страница 50: ...2 Mounting and dismantling 2 16 Festo P BE CPX P EA EN en 1209NH English...
Страница 51: ...Input module CPX P 8DE N 3 1 Festo P BE CPX P EA EN en 1209NH English Chapter 3 Input module CPX P 8DE N...
Страница 113: ...Technical appendix A 1 Festo P BE CPX P EA EN en 1209NH English Appendix A Technical appendix...
Страница 125: ...Index B 1 Festo P BE CPX P EA EN en 1209NH English Appendix B Index...
Страница 126: ...B Index B 2 Festo P BE CPX P EA EN en 1209NH English Table of contents B Index B 1...
Страница 132: ...B Index B 8 Festo P BE CPX P EA EN en 1209NH English...